AmstradCTV1410Onwa
Field cramp atbottomR408 18k o/c
AmstradCTV1410 Onwa
Sw itself back on when in st/by - intFlexing panel brought fault on - R920 & R302 were physically touching bypassing relay
AmstradCTV1410 Onwa
Dead with HT low at 50v (112v)No st/by relay, R632 33k pin 36 IC603 o/c
AmstradCTV1410
Vol at max, osd perm on, no tuningMN1220 EEPROM - use Alba version (cheaper)
AmstradCTV1410
No sound or raster.ZD301 ( 9.1zener ) s/c.
AmstradCTV1410
No pic - faint raster when A1s advancedNo scastle pulses pin 17 IC301 - R316 12k o/c
AmstradCTV1410
No or int no frame scan.C403/4/5.
AmstradCTV1410
No colour on picture - OSD colours Ok.C322 ( 22nf ) low.
AmstradCTV1410
No chan storeNo -30v to eeprom - C602 10nF
AmstradCTV1410
Low emission tube symptomR650 & R651 4k7 hi res
AmstradCTV1410
Int frame collapse.Change C401 ( 1nf ) , C403 ( .1uf ) , C404 ( 0.022uf ) , C405 ( 1nf )
AmstradCTV1410
Height reducedR302 6k8 hi res
AmstradCTV1410
Field roll on bright scenesC304 2µ2
AmstradCTV1410
Dead - chopper tr 2SD1545 blownCheck Q902 2SB774, ZD902 9v1 zener
AmstradCTV1410
Deado/c relay contacts RLY901


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.