Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CPD1310 | UNIT IS DEAD | Unit is not developing high voltage. Low B+ (46V) of D6007(instead of 115V B+) low 17V (2V). Decreased value capacitor C6007 330uF/25V. | ||
Sony | CPD1310 | INTERMITTENT LOSS OF PICTURE OR RED VIDEO | Unit would loose video red or raster would blank. Movementof connector CNJ401 would cause problem. Etch around terminal connectionswas broken. | ||
Sony | CPD1310 | NO VIDEO | Circuit board broken on B board underneath of CNJ401 alltraces broken. This is the second set with the same symptoms, and alsoD416, 417, 418 went bad. |