Dicas Reparação




Modelo - Chassis CPD1303


Pesquisa: CPD1303 Enviar Dica Resolvida
Resultados 8
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyCPD1303
RECOMMENDED SCREEN CLEANER
SonyCPD1303
CURVATURE OF THE CRT What is the curvature of the CRT? -HQ COMMENTS: Radius of the curvature for the CRT is: Side to sideR = 660mm. Top to bottom = flat (infinity). Corner to corner R = 1015mm.
SonyCPD1303
MISSING PART NUMBER ON SERVICE MANUAL The mounting screws for the 9 pin (d type) connector arespecified as part number 768564679. This is the correct mountingscrew for the AC Connector but not for the 9 pin connector. The screwneeded is shown on page 45 of the service manual. It is the sc
SonyCPD1303
SHUTDOWN AFTER WARMUP Ohm meter check between HVR and GND measures 100K - 120K Ohms:too high. Both part numbers above sub to 1-230-666-21, which normallymeasure 100K ohms or slightly less: ok.
SonyCPD1303
VERTICAL FOLD AT TOP OF SCREEN Vertical fold at top of screen. 80 volt measured on 15 volts.T-654 secondary open.
SonyCPD1303
FLAGGING AT TOP OF SCREEN WHEN USED WITH MAC II After about one hour of operation, a flagging would start attop of screen when used with MAC II. This problem would not be seen withmultiscan generator at Macintosh II frequency.
SonyCPD1303
SLIGHT BEND IN VERTICAL LINES Very slight bend in vertical lines at top one inch of screen.I was suggested that I try to modify AFC circuit to resolve complaint.
SonyCPD1303
STATIC SHOCK 1) Static shocks when touching chassis/screen 2) A spark ofstatic when removing screws of the back cover -HQ COMMENTS: We found the static at CRT surface exist only when the setis turned off. However when the set is on, there is no static on thescreen


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.