Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CFS9000 | UNIT DOES NOT RECORD IN REV DIRECTION | Unit is different than print. It does not have a reverserecord proof button. -HQ COMMENTS: This is an E model unit, not the US model. It only hasrecord in one direction. | ||
Sony | CFS9000 | EXCESSIVE VOLUME AT LOW SETTINGS - AV POWER ONLY | With AC power there is excessive volume on low settings.Battery operation OK. Problem was excessive voltage on the 13.6V line.This line powers the output IC and when using AC power reads 39V. Checkedthe transformer output and found the red secondary le | ||
Sony | CFS9000 | TRACKING NOISE IN AUDIO | When using the D-14 and the CFS-9000 on the same DC source,there is a noise in the audio that is equal to the tracking changes onthe D-14. The noise can be seen all over the D-14 including the ground,when the scope ground is connected to the DC supply g | ||
Sony | CFS9000 | HEAD WOULD NOT ENGAGE | Head bracket assy (X-3319-204-1) was broken on the headrotator. | ||
Sony | CFS9000 | COMPLETE MECHANISM - P/N MISSING | Need part number for complete cassette mechanism. -HQ COMMENTS: The tape transport is not available. | ||
Sony | CFS9000 | BROKEN GEAR OF HEAD BRACKET ASS | The gear seems so hard. It is easily broken. |