Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDXR77 | NO AUDIO, IC301, Q409, Q412 OPEN OR SHORTED | Q409, Q412 had higher than normal temperature and opened.Intermittently IC301 shorted +5v to gnd. | ||
Sony | CDXR79 | SKIPPING WHEN OUTER TRACKS ARE PLAYED | The customer may complain that skipping occurs when outertracks of discs are played. This may occur if the mechanism sub-chassisis bent, which makes it more difficult to maintain proper focus at theouter portions of discs. | ||
Sony | CDXR77 | SKIPPING WHEN OUTER TRACKS ARE PLAYED | The customer may complain that skipping occurs when outertracks of discs are played. This may occur if the mechanism sub-chassisis bent, which makes it more difficult to maintain proper focus at theouter portions of discs. | ||
Sony | CDXR79 | SWITCHES FROM TUNER TO CD AT RANDOM (REPLACE SW622) | While playing the radio, the unit reverts to CD operation evenif no CD has been inserted. | ||
Sony | CDXR77 | SWITCHES FROM TUNER TO CD AT RANDOM (REPLACE SW622) | While playing the radio, the unit reverts to CD operation evenif no CD has been inserted. | ||
Sony | CDXR79 | EJECTS DISC PREMATURELY (UNIT MOUNTED AT 45 DEGREE ANGLE) | This unit is mounted at an approximately 45 degree angle in aconsole on top of the transmission. Intermittently it will eject or nottake a disc. Are there restrictions on the angle of installation? Wouldheat from the transmission cause the unit to eje | ||
Sony | CDXR77 | EJECTS DISC PREMATURELY (UNIT MOUNTED AT 45 DEGREE ANGLE) | This unit is mounted at an approximately 45 degree angle in aconsole on top of the transmission. Intermittently it will eject or nottake a disc. Are there restrictions on the angle of installation? Wouldheat from the transmission cause the unit to eje | ||
Sony | CDXR79 | AM SEEKS IN 9KHZ STEPS | AM seeks in 9kHz steps. Is there a combination of buttons todepress to convert to 10kHz USA mode as on some other models? | ||
Sony | CDXR79 | SERVICE MANUAL ADJUSTMENT SECTION ERRORS | The adjustment section of the manual has several errors. Onpage 11, shouldn't spindle height be closer to .95mm than .95cm? On pages12 and 13, the diagrams show the scope connected to ground. I believethe proper reference is Vc (2.5V) for any RF amp a | ||
Sony | CDXR77 | SERVICE MANUAL ADJUSTMENT SECTION ERRORS | The adjustment section of the manual has several errors. Onpage 11, shouldn't spindle height be closer to .95mm than .95cm? On pages12 and 13, the diagrams show the scope connected to ground. I believethe proper reference is Vc (2.5V) for any RF amp a | ||
Sony | CDXR79 | WILL NOT EJECT | Ratcheting noise when unit is trying to eject. | ||
Sony | CDXR79 | SKIPS | Skips on all discs. Found spindle motor did not have suffi-cent torque. | ||
Sony | CDXR77 | SKIPS OVER BUMPS - MORE SENSITIVE THE LONGER UNIT IS ON | Skips, adjusting did not completely solve the problem. Foundspindle motor lacking torque. | ||
Sony | CDXR79 | INCORRECT PART NUMBER - L403 | The part number listed in the S/M does not come up as valid inthe KCP parts system. What is the correct P/N? -HQ COMMENTS: Tokyo Fax TX-USA91086. Correct P/N for this inductor is1-410-524-41. Refer to Car (CSA-14) Service Bulletin No. 204. | ||
Sony | CDXR79 | SKIPS DURING TRACKS 3-5 | Burbank informed me that he has had complaints where the unitwill skip or stop on track 3 or 5. He installs a piece of plasticbeneath the metal clip which holds the ribbon cable (larger one) close tothe FOP body to extend the ribbon connector. He says |