SonyCDX65
ERASING ALL DISC TITLES AT ONCE (CUSTOM FILE) The CD changer may not display NO DATA after servicebulletin #330 has been executed.
SonyCDX65RF
PART AVAILABILITY: HIDEAWAY/WIRED DISPLAY The manual has no part number for Hideaway units and WiredDisplays that are defective and cannot be repaired to component level.
SonyCDX65RF
SKIPS WHEN PLAYING OUTER TRACKS (SEE BULLETIN 358R2 FOR FIX) The unit skips when playing the outer (higher number) trackson the disc.
SonyCDX65
SKIPS WHEN PLAYING OUTER TRACKS (SEE BULLETIN 358R2 FOR FIX) The unit skips when playing the outer (higher number) trackson the disc.
SonyCDX65
SCREW USED IN SB 358R1 UPDATE STRIPS AND BECOMES LOOSE SB update # CAR 0358R1 calls for a screw part 7-621-255-01, tobe used to hold down the new cover in the bulletin mentioned. However, Ifound that this type screw strips when installed, which becomes loose.The screw is machine type thread.
SonyCDX65RF
COMPRESSION SPRING MISSING Mechanism jammed and discs are stuck inside. Found that thecompression spring (ref. 61) was not in the unit.
SonyCDX65
SERVO PCB INCOMPATIBILIITY After replacing SERVO PCB there is no elevator & no load/save.
SonyCDX65
RESETS WHEN POWERED UP, WON'T DO ANYTHING ELSE Unit will reset when powering up but won't do anything else.Inspecting further, data line and clock line won't go high.Data line and clock line were shorted with each other. In closeinpection, found a copper strand from wire inside unilink connector CN8
SonyCDX65
WON'T RESET WHEN POWERED UP (REPLACED SW902,Q903,D905,D906) Unit won't reset when powering the unit. If you load themagazine it will reset but won't do anything else. Inspected MD boardQ903 was overdissipated, found SW902 was shorted. -SOLUTION Replace SW902 1-692-864-11, Q903 8-729-808-01, D9058-719-105-99,
SonyCDX65RF
1 DISC NOT EJECTED (REPLACED REF. 60 AND REF. 205) Unit came in with one CD stuck inside. Looks as if cust triedremoving all discs but one. Noticed MD assy was not chucked down. Resetunit and unit ejected disc, but when attempt to play disc elevator stopsmoving but you could hear that the elevator mot
SonyCDX65RF
DOES NOT LOAD CD'S; MAKES NOISE (FOUND REF. 221 DAMAGED) Customer complaint: constantly will not play. Open unit tocheck, found does not take any CD into roller. #164 slide lever and 221gear made noise when trying load discs.
SonyCDX65RF
PART # CORRECTION: Q503 (CORRECT PART # IS 8-729-204-10) Found part # for Q503 8-729-240-10, was not in system (FIPM).Looked in semi-conductor replacement handbook and found that the # for2SD1417 is actually 8-729-204-10 (page 700 of 1992 2nd SRM). We had thepart in stock and the unit was repaired.
SonyCDX65
DOES NOT LOAD CD'S; MAKES NOISE (FOUND REF. 221 DAMAGED) Customer complaint: constantly will not play. Open unit tocheck, found does not take any CD into roller. #164 slide lever and 221gear made noise when trying load discs.
SonyCDX65RF
CONTROLLER'S DISPLAY SHOWS "FULL" WHEN ENTERING TITLES The changer controller's display may show FULL when tryingto enter disc titles, even though the customer has not yet entered themaximum of 110 disc titles. This problem occurs because some units didnot have the factory-entered titles erased before they
SonyCDX65
CONTROLLER'S DISPLAY SHOWS "FULL" WHEN ENTERING TITLES The changer controller's display may show FULL when tryingto enter disc titles, even though the customer has not yet entered themaximum of 110 disc titles. This problem occurs because some units didnot have the factory-entered titles erased before they


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.