Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDPC85ES | INTERMITTENT SHUT DOWN - REPLACED D913 | Unit would play perfectly for a time. 5 mins to severalhours. When in failure mode, laser would return to home position andun-chuck the disc. CLV motor may also spin rapidly. | ||
Sony | CDPC85ES | NEW DISC TABLE FROM KCP HAS ONE HOLE PER DISC INSTEAD OF 2 | I ordered ref. No. 53 disc table (P/N 4-726-383-11) andreceived one with only one small hole and a slot instead of two holes. Ithen ordered No. 69, A-4604-533-A disc table assembly which included adisc table with two holes per disc. | ||
Sony | CDPC85ES | TORN PRINT ON PCB | When you remove IC-102 with Pyro pen, too much glue has beenput underneath IC. When you try to remove the IC, the print tears up thecircuit board. -HQ COMMENTS: The glue used is necessary during the manufacturingprocess to secure the components to the | ||
Sony | CDPC85ES | DISC SPINS DOES NOT READ TOC | A new A stock unit the Laser is firing, disc spins, but theinformation is not being read. A very poor RF pattern is observed whenthe player is trying to read TOC. The lens is popping up and downapparently trying to focus and the motion of the lens is r | ||
Sony | CDPC85ES | DISC TABLE WILL NOT ROTATE | On some units the bracket which houses the optical devicecontacts the base of the player. This causes the table not to rotate orthe disc not to play. -HQ COMMENTS: The cause of the problem is the metal base warping upward.When the bracket drops it does |