SonyCDPC85ES
INTERMITTENT SHUT DOWN - REPLACED D913 Unit would play perfectly for a time. 5 mins to severalhours. When in failure mode, laser would return to home position andun-chuck the disc. CLV motor may also spin rapidly.
SonyCDPC85ES
NEW DISC TABLE FROM KCP HAS ONE HOLE PER DISC INSTEAD OF 2 I ordered ref. No. 53 disc table (P/N 4-726-383-11) andreceived one with only one small hole and a slot instead of two holes. Ithen ordered No. 69, A-4604-533-A disc table assembly which included adisc table with two holes per disc.
SonyCDPC85ES
TORN PRINT ON PCB When you remove IC-102 with Pyro pen, too much glue has beenput underneath IC. When you try to remove the IC, the print tears up thecircuit board. -HQ COMMENTS: The glue used is necessary during the manufacturingprocess to secure the components to the
SonyCDPC85ES
DISC SPINS DOES NOT READ TOC A new A stock unit the Laser is firing, disc spins, but theinformation is not being read. A very poor RF pattern is observed whenthe player is trying to read TOC. The lens is popping up and downapparently trying to focus and the motion of the lens is r
SonyCDPC85ES
DISC TABLE WILL NOT ROTATE On some units the bracket which houses the optical devicecontacts the base of the player. This causes the table not to rotate orthe disc not to play. -HQ COMMENTS: The cause of the problem is the metal base warping upward.When the bracket drops it does


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.