SonyCDPC700
PART NUMBER MISSING-TRANSIT LOCK KEY There is no part number listed in the manual for the transitlock key. Please supply the part number. -HQ COMMENTS: To Tokyo: This is a necessary part for service. Pleasesupply the part number. Is it the same as the transit lock key for theCDP-C400/50
SonyCDPC70
BROKEN PULLEY CHUCKING I have found the Pulley Chucking broken in several units. Ihave replaced the Pulley Chucking and on a few units they have come backin a few weeks with the same problem. I found by melting and spreadingout center of the Pulley Chucking so it overlaps th
SonyCDPC70
REPLACEMENT FRAME ASSEMBLY FOR CDP-C50 Support post for gear (Loading C) is not part of replacementframe assembly. The frame requires replacement when the post holding partNo. 61 set lever breaks. Rather than undergoing the monumental task ofreplacing this entire assembly, only to have to m
SonyCDPC70
NO MUTING WORKS DURING PROGRAM AND SHUFFLE MODE There is a moment noise just before the beginning of the nexttrack in. Program or shuffle mode on certain (disc - not all) sample discof customers is the Cars Greatest Hits manufactured for RCA. Noise showson this disc between 7-9 tracks in program mod
SonyCDPC70
NON CAMPATIBILITY OF SOME COMPACT DISCS Both models (CDP-C70 and CDP-C40) will not play track No. 1 onthe following Warner Bros./Reprise CDs:1. Seals and Crofts/Greatest Hits, WB3109-2 - SR005.2. Gordon Lightfoot/If You Could Read My Mind, Reprise 6392-2 -SRC01Unit will play any other track on


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.