Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDPC215 | NO MECHANICAL ACTION | Original problem, no mechanical action. IC401 was replacedand now all functions work except the next disc will not be played. Thenext disc will be selected and it will chuck but will not spin. A newboard, with the latest IC, was ordered and it acts the s | ||
Sony | CDPC215 | NO OPEN/NO FUNCTION CONTROLS (REPLACE C431 P/N 1-162-294-31) | Unit would not open and front panel controls wereinoperative measured key inputs of IC401 and found key 6 to be at 0V.Checked C431, found C431 to be partially shorted. | ||
Sony | CDPC215 | SKIPS AFTER REPLACING SPINDLE MOTOR (ADJUST TABLE HEIGHT) | Skips in normal position but, plays O.K. on side. Adjustmentswould not help. | ||
Sony | CDPC215 | INTERMITTENT OPEN AND NO OPEN DISK SKIP (RESOLDER M701) | The unit intermittently opened, and there was no disk skip.Upon diagnosis of unit, I found a cold solder joint on the negativeterminal of the table motor M701. | ||
Sony | CDPC215 | STOPS PLAYING AFTER 1 MINUTE (REPLACE IC-401) | Unit stops playing after one minute, then it will not read thenext disc. | ||
Sony | CDPC215 | VARIOUS PROBLEMS (RESET NOT WORKING) FLEX CABLE REF. 101 BAD | This unit would manifest a variety of odd problems, includingno play. Noticed that RESET on IC-202 was not going to 0V as required.It stayed at around 3V. Found a break in the ground lead of flexconnector between Main and BD board. This robbed the BD | ||
Sony | CDPC215 | DISC TABLE ROTATES CONSTANTLY | Disc tray would rotate constantly when powered on. Could notopen or close tray. | ||
Sony | CDPC215 | DISC DRAWER DOES NOT CLOSE | Drawer would not close. Disc table would rotate. | ||
Sony | CDPC215 | DIM DISPLAY | The display was very dim. | ||
Sony | CDPC215 | HIGH PITCH NOISE FROM LINE OUT AND HEADPHONE OUT | Flex cable ref. 6 insulation tears and shorts to chassiscausing a high pitched noise from the line out and headphone outputs. Thedisplay is also irratic. |