Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDPC211 | STATIC WHEN PLAYING - IC301 DEFECTIVE | Noise in audio output, static with music, I found IC301 on themain board defective (IC301 Digital signal processor). | ||
Sony | CDPC211 | NO OPEN/NO FUNCTION CONTROLS (REPLACE C431 P/N 1-162-294-31) | Unit would not open and front panel controls wereinoperative measured key inputs of IC401 and found key 6 to be at 0V.Checked C431, found C431 to be partially shorted. | ||
Sony | CDPC211 | SKIPS AFTER REPLACING SPINDLE MOTOR (ADJUST TABLE HEIGHT) | Skips in normal position but, plays O.K. on side. Adjustmentswould not help. | ||
Sony | CDPC211 | STOPS PLAYING AFTER 1 MINUTE (REPLACE IC-401) | Unit stops playing after one minute, then it will not read thenext disc. | ||
Sony | CDPC211 | INTERMITTENT OPEN AND NO OPEN DISK SKIP (RESOLDER M701) | The unit intermittently opened, and there was no disk skip.Upon diagnosis of unit, I found a cold solder joint on the negativeterminal of the table motor M701. | ||
Sony | CDPC211 | VARIOUS PROBLEMS (RESET NOT WORKING) FLEX CABLE REF. 101 BAD | This unit would manifest a variety of odd problems, includingno play. Noticed that RESET on IC-202 was not going to 0V as required.It stayed at around 3V. Found a break in the ground lead of flexconnector between Main and BD board. This robbed the BD | ||
Sony | CDPC211 | DISC TABLE ROTATES CONSTANTLY | Disc tray would rotate constantly when powered on. Could notopen or close tray. | ||
Sony | CDPC211 | DISC DRAWER DOES NOT CLOSE | Drawer would not close. Disc table would rotate. | ||
Sony | CDPC211 | DIM DISPLAY | The display was very dim. |