Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDV801 | NO LANC OPERATION/NO REMOTE FUNCTION - W201 COLD SOLDER | RM95 not powering up/no function when connected to remoteconnector and no remote control function. | ||
Sony | CCDV801 | SLOW PLAY HAS LINES (CAME IN WITH BAD VIEWFINDER) | Slow play had intermittent snow in it. Path was correct andwould not adj. properly with menu by data screen controls. Back tensionwas at 9g/cm. Still play slow. Regular record and play were good. | ||
Sony | CCDV801 | CIRCUIT BOARDS ARE DIFFERENT/SM SUPP-2 | |||
Sony | CCDV801 | AUTOFOCUS HUNTING | Customer complained of autofocus hunting of camera. Servicerwas able to restore what appears to be correct operation by changing datain address 38 from 48 to 38. This adjustment is not explained in servicemanual. Please advise. -HQ COMMENTS: Address | ||
Sony | CCDV801 | NEED PART NUMBER FOR THE DRUM BASE | I need the drum base for a CCD-V801. The manual shows itas part of the drum assembly. It is not included when ordering the drumassembly.-HQ COMMENTS: A service bulletin will be issued on this soon. The partnumber is X-3686-482-5 and is in stock in KCP. | ||
Sony | CCDV801 | ERROR IN SERVICE MANUAL PAGE 137 | On page 137 of the service manual it shows IC-910/pin 1 goingto both ground and 4.8V VDD through a 0 Ohm resistor. Obviously, B+ andground are not connected together. |