Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDV110 | NO LUMINANCE | After warm up period lost luminance. | ||
Sony | CCDV110 | NO CAMERA POWER | Unit came in no camera power. Found F901 blown DC-DCconverter (DR901) OK. Found CN003 DR901 (should go to EM-1 boardconnector 901) going to AU-24 board CN403. Both connectors are 2 pinred and gray wires and apparently were switched in manufacturing. | ||
Sony | CCDV110 | POWER UP ONLY | Power up but no transport functions due to no drum rotation. | ||
Sony | CCDV110 | ZOOM NOT WORKING CORRECTLY | Zoom switch ran one direction only towards wide not telephoto.Found B+ wired to one side of switch and not center. | ||
Sony | CCDV110 | PLAYBACK NO Y INFO AND CAMERA NO ZOOM, NO VIDEO | 1) Traced Y info around VTR back to Pin 2 of VY-8 board buthad no out at Pin 21, traced to no info at Pin 37 of IC0001 on VY-8 buthad info on C049 coupling cap. IC side of cap was soldered but not toland PC. 2) Developed after repair of first problem. | ||
Sony | CCDV110 | IC | IC801, 802, 803 on AF-23 board have no P/Ns in S/M. -HQ COMMENTS: Please refer to the CCD-V5 service manual, AF board, forthe IC part numbers. | ||
Sony | CCDV110 | "X" MARK ON DDS IS BLINKING | Customer says X mark on DDS is blinking (see page 174 ofS/M). Operating instructions do not mention this indication. Allfunctions seem normal on unit. -HQ COMMENTS: The X mark indicates dirty video heads. Please advisethe customer to bring in the uni | ||
Sony | CCDV110 | S/M PAGE 20 WHAT IS NATRIUM LAMPS? | Page 20 list natrium lamps under difficult conditions forlinear auto W.B. -HQ COMMENTS: Natrium is the same as sodium vapor lamps. |