Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDV110 | NO PICTURE IN CAMERA MODE | No picture in camera mode. | ||
Sony | CCDV110 | UNIT DEAD | Open fuse F381 on the SC-6 board. Tape inside unit. -HQ COMMENTS: Please try to determine the mode of operation duringfailure and check for bent pins on the multipin connector if you receiveany similar units. | ||
Sony | CCDV110 | NO PLAYBACK VIDEO | No video on playback. Appeared to have defective video heads.RF output from heads, and head amp normal. Found loss of gain in Q227 onVI-21 board. | ||
Sony | CCDV110 | CAMERA WOULD FLASH BRIGHT/DARK | Video from camera had what appeared to be incorrect horiz.freq. and would flash bright/dark. Playback from VCR section OK.Found X701 on the CP-18 board had no CW output. The output pulsed, butwould not ring. | ||
Sony | CCDV110 | MULTIPLE IMAGE IN VIEWFINDER AND POOR SOUND | Multiple image in viewfinder and poor sound. | ||
Sony | CCDV110 | UNIT WOULD NOT POWER-UP | Would not power up. | ||
Sony | CCDV110 | X303 REPLACEMENT PART | Need P/N for X303 on SS-64 board, 4mHz crystal. Replacementpart physically too large. -HQ COMMENTS: Replacement part is physically different, but does fitin holes in PC board. Checking stock for misorder or mixed stock. | ||
Sony | CCDV110 | VIEWFINDER CHARACTORS | Viewfinder will only tell date, time, main and sub titles.Everything functions properly. Just missing charactor information. | ||
Sony | CCDV110 | INT. LOSS OF PICTURE SYNC | This unit would int. loose the picture sync. This was causedby the crystal changing frequency. | ||
Sony | CCDV110 | AFTER 10 MINUTES PICTURE DISTORTS - CAMERA ONLY | After 10 or 15 minutes picture would loose color and turn tohoriz. streaking lines on camera only. | ||
Sony | CCDV110 | POOR PIX AND SOUND | Multiple image in viewfinder and poor sound. | ||
Sony | CCDV110 | PICTURE FLUTTER UNDER CERTAIN LIGHTING | The VTR works fine. However, when the camera has the upper1/3 in bright light and the lower 2/3 is relatively dark there is anoticeable flutter in the playback picture. This is not seen in the EVF.We have gone through the iris and agc adjustments with | ||
Sony | CCDV110 | SCRAMBLED IMAGE | This unit had a scrambled image in the view finder andrecorded on the tape. It appeared as though, the horizontal was offfrequency, because of the horizontal lines in the picture. | ||
Sony | CCDV110 | VERT ROLL IN VIEWFINDER | Viewfinder had vertical roll from camera input only. Founddistorted sync signal at Pin 47 of IC703 on CP-18 board. Sync input atPin 3 of IC703 on CP-18 board checked normal. Replaced IC703 on CP-18board, problem resolved. | ||
Sony | CCDV110 | NO VIEWFINDER CHARACTERS DISPLAY | This unit had no character display in the viewfinder. Thecharacter generator IC was found to be defective. The on tape characterswere OK. |