Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDF55 | NO PIX FROM VTR, NO PB RF (FOUND OPEN TRACE ON SS100 BOARD) | When camcorder is in play mode, no picture. No RF on pin 3of CN508 (PBRF testpoint). Also missing was switching 5V (REC/PB) on pins11/12 of CN501 and pin 25 of IC506. Also missing was 5V on pin 27 ofsame IC. Found power line 5V open between L502 and | ||
Sony | CCDF55 | PIX ROLLING IN VIEWFINDER / REPLACE C438 | Received unit with multiple problems, after replacing capskit most problems resolved. Except pix is rolling in viewfinder. After troubleshooting, traced back to C438 which found a bad new capacitor. | ||
Sony | CCDF55 | NO RECORDED COLOR / REPLACE C206 ON THE VA-46 BOARD | NO RECORD COLORSOLUTION: REPLACED LEAKY C311 ON VA46 BOARD | ||
Sony | CCDF55 | DATES DON'T DISPLAY CORRECTLY - EUROPEAN STYLE | Dates would not display properly in viewfinder after theVC-100 board was changed. To remedy the problem, the data at Page Daddress 01 was changed from 3B to 59. This address appears to designate several of the features/modes for themodel, i.e. the date | ||
Sony | CCDF55 | JAPANESE CHARACTERS FOR MONTH ON OSD, LCD DISPLAY OK | Due to water damage, we had to replace the CT21 board on thisunit. After installation, we could not get the OSD to display the datecorrectly. Either it was yy/mm/dd or mm/dd/yy, but with the month inJapanese characters. | ||
Sony | CCDF55 | DRUM RUNS VERY SLOWLY, TAPE WILL NOT LOAD/C513 LEAKS | Drum runs slow, tape will not load. | ||
Sony | CCDF55 | NO VIDEO FROM CAMERA BLOCK/RESOLDER W801 | Technician replaced DT and MX boards for no video problem,camera block. No video output frompins 24/25 of the MX board. All inputsignals were correct, including clamp pulsed. YH in, and XDL1,2. | ||
Sony | CCDF55 | EVF PART NUMBER (FPR M0495) | CCDF55 may use a round CRT or a square CRT. The CRTholders are therefore, different. | ||
Sony | CCDF55 | INTERMITTENT PICTURE DISTORTION/REPLACE HEAD AMP | Picture would have intermittent fuzzy appearance on straightobjects when tape played back. Checked RF out. Found frequenceycharacteristics of 1 head to change intermittently. Tapping on unitcaused it to go away. Found problem more sensitive near head | ||
Sony | CCDF55 | P/N FOR C911, VF 26 NOT IN SYSTEM/USE 1-131-388-00 | The above part number isn't listed in the system. -HQ COMMENTS: This part number subs in Tokyo to 1-131-388-00. Use thispart number. | ||
Sony | CCDF55 | RINGING IN VIEWFINDER/CHECK C909, VF26 BOARD | Ringing in viewfinder. C909 was open. | ||
Sony | CCDF55 | IRREGULAR CAPSTAN SPEED/CHECK CONNECTOR FP-248 | Intermittent speed up of the capstan motor. | ||
Sony | CCDF55 | DEAD/REPLACE F991 AND C317 (VA46 BOARD) | Dead unit. F991 open. Short circuit on video 4.9v line. | ||
Sony | CCDF55 | DATE AND TIME LOST AFTER BATTERY IS REMOVED | When main battery was removed, date and time would be lost.Customer tried several Li batteries. | ||
Sony | CCDF55 | NO CAMERA/VTR OK/CHECK CN601 - CN508 CONNECTION | No camera but VTR ok. The dc to dc converter would not turnon. |