Won't come out of st/by when sw to st/by aft operating for more than 5 mins Sw mode Tr replaced
MitsubishiBDS28WS11AK19PRO
Sw to st/by aft 2 mins - G LED flasheswhen trying to come out of st/byD505 2v4 zener sm conn to pin 33 IC501 leaky
MitsubishiBDS28WS11AK19PRO
DeadQ605 BU2508AF, C630 390NF 250V, C626 12NF 2000V, L604 E/W Coil, TR601 Line drive transformer, L604 15mH Coil, R629 27R, D807 BA159, D605 BA159, D606 BA159, C835 1nF 1000V
MitsubishiBDS28WS11AK19PRO
11AK19
Won't come out of st/by when sw to st/by aft operating for more than 5 minsSw mode Tr replaced
MitsubishiBDS28WS11AK19PRO
11AK19
Sw to st/by aft 2 mins - G LED flasheswhen trying to come out of st/byD505 2v4 zener sm conn to pin 33 IC501 leaky
MitsubishiBDS28WS11AK19PRO
11AK19
DeadQ605 BU2508AF, C630 390NF 250V, C626 12NF 2000V, L604 E/W Coil, TR601 Line drive transformer, L604 15mH Coil, R629 27R, D807 BA159, D605 BA159, D606 BA159, C835 1nF 1000V


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.