SharpCS 59/66CS03H
dead, LOPTr s/creplace LOPTr BUH515, R604 39R (burnt), C606 680nF 250V (leaky)
SharpCS 59/66CS03H
deadblue disc cap C601 8200pF 2kV s/c (located under D605 on the print side)
SharpCS 59/66CS03H
deadSound output stage s/c. repalce Q311(RHTX0147BMZZ), Q312 RHTX0148BMZZ), D308 (RHDX0503BMZZ) and check for DJs on heatsinks.
SharpCS 59/66CS03H
bright white raster with flyback linesSMD D618 near LOPTx o/c (RHEX0542BMZZ)
SharpCS 59/66CS03H
at loud bass sound goes to stby (same on RF or SCART)sat and cable sound input levels sometimes too high and fool TV into protection mode. No cure, advice customer to reduce volume (ref. Sharp-technical)
Sharp66CS03H
St/by onlyRipple on 5v supply caused by C714 1000µ 10v low cap
Sharp66CS03H
SLOW START FROM COLDREPLACE C714 1000MFD10V
Sharp66CS03H
Out of focus col blobs in raster & no sound45v to fop & audio stages missing. R643 5R6 o/c & D623 10v zener cooked but R643 overheats when sw on. Remove Q509 (fop feed) ; no -13v at Q508 emitter as R631 o/c; ok when former replaced
Sharp66CS03H
Line o/p tr BUH515 int blows at sw onC604 330µ 10v
Sharp66CS03H
INTERMITTANT BLOWING OF Q601/Q701REPLACE C604, R638 AND R641
SHARP66CS03H
FRAME BOUNCE WITH ROLL ON TEXTREPLACE C604 330MFD10V
Sharp66CS03H
Field scan distorted in upper half45v supply at C619 only 15v. R643 5R6 overheating, D623 10v zener sm leaky, R632 1A cct prot o/c
SHARP66CS03H
DEAD BUT COMES ON AFTER A WHILEREPLACE C714 1000MFD25V
Sharp66CS03H
Dead - LOPtr s/creplace C604, C714 & check dry joints scan coil pcb
Sharp66CS03H
DEADCHECK C601 FOR S/C (FITTED UNDER D605 ON PRINT SIDE IS BLUE DISC TYPE)


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.