Dicas Reparação




Modelo - Chassis 59CS03H


Pesquisa: 59CS03H Enviar Dica Resolvida
Resultados 14
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Sharp59CS03H CS
Dead - psu dead (give up now!)Chopper MOSFET s/c, R706, D718, 2 x BC338 got psu working on dummy load - LOP Tr s/c, D601 1N4935 in 13v supply s/c, now have pin cush dist - D619/621 s/c
Sharp59CS03H
No Txt or OSDHad fallen to zero in user menu - possibly by flash over? - sorry, no instructs here - try user
Sharp59CS03H
No sound - headphone ok22R 0.5w safety res on 40v rail from loptx o/c
SHARP59CS03H
NO SOUNDCHECK R643 FOR O/C 5.6 OHM
Sharp59CS03H
No BlueB drive was et to zero in service menu (vol down/chan up whilst sw on)
Sharp59CS03H
No / int field collapseResolder L501 ( joints on body )
Sharp59CS03H
Field lin creeps up at bottomQ707 C33840 = BC338-40
Sharp59CS03H
Dead & whistlingQ306 2SA1797Q sm audio amp s/c - also check Q306, D301/2, D305 1N4933 & check for dry joints back of scan coil pcb
Sharp59CS03H
DeadTDA8375A IF/video proc/tbase chip faulty IC201 (low res between pin 56 & Chassis)
Sharp59CS03H
Audio noise - intQ305/306
Sharp51CS03H 59CS03H
Stuck in StBy .If no 300v across C708 check for continuity from D704 cathode to L703 . PCB sometimes damaged in transit .
Sharp51CS03H 59CS03H
Int flyback lines ( may be red , greeen or blue )Flux becoming conductive on Q870 , 871 , 872 . remove transistors , clean pcb and transistors and replace .
Sharp51CS03H 59CS03H
Int bleep from speakers or int no sound ( when hotAdd wire link from pin 22 IC301and pins 28 , 29 ( Gnd )
Sharp51CS03H 59CS03H
Field fault , or general modification .Add 1N4148 from emitter Q509 to cathode D513 ( cathode to E Q509 . Pt No RH-DX0045BMZZ ) . Change R534 for 390R ( Pt No VRS-T


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads