SintomaCausaSoluçãoPor:
SharpDA100 56FW53H, etc
modificationSharp advise to fit avalanche diode (RHEX0875BMZZ) across C720 (150V rail smoothing cap) to limit any damage in event of a fault in PSU
SharpDA100 56FW53H, etc
frame cramp at top or int. frame collapseC502 470uF 25V
SharpDA100 56FW53H
tripping at start-up, LED flashing on/off, will come on after 30 minIC1001 micro RHIX1686BMZZ, may be proven using hairdryer/freezer
SharpDA100 56FW53H
no NICAM, 'mono' on screen displayIC201 TDA4472MFL (RHIX1672BMZZ)
SharpDA100 56FW53H
excessive width, about 4'' too wideQ506 leaky (RHTX0151BMZZ)
Sharp56FW53H
Service mode accessSwitch on with vol down & Ch up buttons pressed. The ch up/down & vol up/down buttons on the handset are used to alter values & each setting must be stored by pressing St/by
Sharp56FW53H
No audioIC302 (TDA7480) l/h audio o/p Ic (about 8ukp from Seme) and two chokes connected to it L315/L316 (3.3microH) (about 1.50ukp packet of 5 from Farnell) were burnt to a crisp.After replacement I still had no l/h audio, found Q306 (2SC2412 sm) s/c in the +5v feed to the Ic (I used a BC847)
Sharp56FW53H
Lines of R, G & B at top of screen & pin cush dist at topNeed to set up NVM values for specific crt type obtained from Sharp Tech bulletins. Also may need to alter geometry settings in service mode.
Sharp56FW53H
Dead - LOPTr s/cFit new BUH515, check for dry joints C613 & C607 330µ 10v hi esr
Sharp56FW53H
Blows LOPTr int at sw onC607 330µ in line driver


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.