(Chassis)
SintomaCausaSoluçãoPor:
SonySLV70HF
EATS TAPES-UNSTABLE PICTURE. SPRING 206, BAND 205,ROLLER 162 Unit would intermittently eat tapes. This happened most oftenat the beginning or end of tape during Cue or Review. Noticed that tapewould skew on capstan prior to being destroyed. The back tensionfluctuates also.
SonyCCDTR71
LC-40 EXTENDER CABLE DOES NOT FIT/ORDER J-6082-189-A Extender jig listed in service manual for CN-41/LC-40 boarddoes not fit the connector on the LC-40 board. Please provide correctpart number for the extender cable. -HQ COMMENTS: Correct part number for this connector is J-6082-189-A. AService Manual Su
SonyTAAV411
AUDIO HUM IN ALL MODES - BROKEN SOLDER CONNECTION ON C954 Unit had bad hum in audio (all modes). Additionally, I neverapply power to a TA-AV411 before carefully inspecting solder on amp-Land Amp-R sub PCB and where the connectors for these PCBs are soldered tomain PCB. These units have had bad solder connect
SonyXR4257
NO FM AUDIO (STATION SEEK OK) On FM, the unit would seek and station detect on FM, but therewas no FM audio or noise. AM was fine.
SonyRD500
IDLER ARM ASSY FROM NPC HAS LOCK WASHER IN WRONG POSITION The washer No. 207 that holds idler No. 229 in place isincorrectly positioned on shaft. Washer No. 207 is positioned on the topgroove of shaft instead of the second groove. Tension spring No. 228 issupposed to connect to the top groove of shaft and the
SonyRD400
IDLER ARM ASSY FROM NPC HAS LOCK WASHER IN WRONG POSITION The washer No. 207 that holds idler No. 229 in place isincorrectly positioned on shaft. Washer No. 207 is positioned on the topgroove of shaft instead of the second groove. Tension spring No. 228 issupposed to connect to the top groove of shaft and the
SonyD34
BROKEN PCB PCB breaks in area of R330 (service manual page 16,coordinates B13). The same problem occured in another unit( Workorder No.W1562489) with different PCB (A-3275-450-A). Maybe the screw No. 24 usedto tighten the board in that area puts too much stress on
SonyCDX5080
EJECTS DISC PREMATURELY (UNIT MOUNTED AT 45 DEGREE ANGLE) This unit is mounted at an approximately 45 degree angle in aconsole on top of the transmission. Intermittently it will eject or nottake a disc. Are there restrictions on the angle of installation? Wouldheat from the transmission cause the unit to eje
SonyDT4
STATIC OR CUTING OUT OF AUDIO - PLACE TAPE OVER RV-301 Static or cutting out of audio in radio mode.
SonySPP320
SPEAKER PART NUMBER New PCB for unit have speaker tabs that protrude through theboard and are soldered on top. The old PCB had contact pad on theopposite side of the board. Problem: cannot use the old speakers with thenew boards. Need part number for new speaker. -HQ CO
SonySPP120
SPEAKER PART NUMBER New PCB for unit have speaker tabs that protrude through theboard and are soldered on top. The old PCB had contact pad on theopposite side of the board. Problem: cannot use the old speakers with thenew boards. Need part number for new speaker. -HQ CO
SonyCDPC525
INTERMITTENT TRAY OPERATION, FLEX CABLE (REF. 56) DEFECTIVE The tray would turn or skip disc intermittently.
SonyWMF2078
NO AUDIO - RESOLDER IC-303/PIN 1 No or intermittent audio in radio or tape. I have seen thisproblem several times before.
SonyCDPH3750
NO CD OPERATION, BU HOLDER ASSY JAMMED INTO BU CAM SLIDER The mechanism section of the five-disc player would move alittle then stop (lock up) at turn on. Upon further investigation I couldsee the BU holder assy. (ref. 81) was binding in the BU Cam slider assy.(ref 118). This type of problem is probably due t
SonySTRAV1070X
NOISE IN SURROUND MODES (HIGH PITCHED REVERB TYPE SOUND) There is a constant high pitched reverb sound (echo) only whensurround modes are used. There is no noise when surround is off.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.