Resultados 81405
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyGV200
PLAYBACK JUMPS ON SELF REC. LP/REPLACE DRUM ASSY Unit will playback pre-recorded SP and LP with no prob. Willplayback self-recorded SP with no prob. But will not playbackself-recorded LP. Pix jumps.
SonyTCWR570
CONTIN. FLSHNG PAUSE LIGHT, NO TRNSPRT CNTRL - RESOLDER T701 When turned on, the unit flashed the PAUSE light, and notransport functions were available. The +/-7V lines were within 10% ofspec. The micro had clock, reset, and the correct program number. Noinputs were inhibiting operation. We replaced the micro t
SonyTCWR511
CONTIN. FLSHNG PAUSE LIGHT, NO TRNSPRT CNTRL - RESOLDER T701 When turned on, the unit flashed the PAUSE light, and notransport functions were available. The +/-7V lines were within 10% ofspec. The micro had clock, reset, and the correct program number. Noinputs were inhibiting operation. We replaced the micro t
SonyTCW411
CONTIN. FLSHNG PAUSE LIGHT, NO TRNSPRT CNTRL - RESOLDER T701 When turned on, the unit flashed the PAUSE light, and notransport functions were available. The +/-7V lines were within 10% ofspec. The micro had clock, reset, and the correct program number. Noinputs were inhibiting operation. We replaced the micro t
SonyTCW370
CONTIN. FLSHNG PAUSE LIGHT, NO TRNSPRT CNTRL - RESOLDER T701 When turned on, the unit flashed the PAUSE light, and notransport functions were available. The +/-7V lines were within 10% ofspec. The micro had clock, reset, and the correct program number. Noinputs were inhibiting operation. We replaced the micro t
SonyTCRX79ES
LOADING PROB, AFTR RPLACMNT OF CAPSTN MTR - REF571 TOO TIGHT After replacement of capstan motor, unit fails to load.
SonySTRGX80ES
NOISE IS PRESENT WHEN SPEAKERS ARE SWITCHED TO B OR A & B Customer equipment is a JVC HRD725U VHS VCR. Sony STRGX80ESspeakers A are at receiver. Speakers B are at patio with 50 feet of wire.When speakers B or A&B are used, AM radio station 1580 KHZ interferes withVHS HiFi audio. VHS HiFi L at 1.3, R at 1.7 M
SonySTRD790
NO AUDIO - CNJ903 NOT CONNECTED Further troubleshooting found that regulators IC971, IC972,and IC973 had no voltage. A visual inspection found that regulator boardconnector CNP903 loose or misconnected from main board connector CNJ903.
SonySTRD611
UNIT IN PROTECT - IC651 DEFECTIVE This unit would go into protect as soon as it tried to comeon. All outputs checked OK.
SonySTRD611
NO POWER - POWER BOARD BROKEN The unit has no power. Checking with volt meter, reveals thatthe traces are broken on the primary side of the transformer (Ref# T902).
SonySTRD590
WRONG PART NUMBER J702 HEADPHONE JACK Order part nubmer in manual and received a 27 pin socketconnector. Need part number for headphone jack.
SonySTRD511
UNIT IN PROTECT - IC651 DEFECTIVE This unit would go into protect as soon as it tried to comeon. All outputs checked OK.
SonySTRD511
NO POWER - T901 OPENED The unit has no power. Further trouble shooting found thatT901 is open.
SonySTRD511
NO POWER - POWER BD CRACKED The unit has no power. Checking with volt meter reveals thatthe traces are broken on the primary side of the transformer (Ref #T902).
SonySTRD390
DEAD - REPLACED OUTPUT TRANSISTORS The unit was dead because R775, R774 and two outputtransistors Q762 and Q763 had overdisipated.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.