Dicas Reparação




Modelo - Chassis


Pesquisa: Enviar Dica Resolvida
Resultados 81405
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyDXAC70
CLICKING NOISE FROM TAPE DECK - REALIGNED GEAR #213 Tape deck clicks and intermittent turning of take upreel, eating tapes because of no take up motion. Problem is caused by nocontact between gear #213 and pulley #215, there is too much clearancecausing intermittent motion.
SonyDXAC70
MHCC70 SYSTEM DEAD - REPLACED SHORTED C106, FILTER CAP System dead, fuses blown.
SonyDXAC70
BAD DISPLAY/NO POWER - SOLDER BRIDGES ON IC821 The unit has bad display or sometimes no power. By a visualinspection of IC821 on panel board, reveals that pins 55, 56 and pins72,73 and 74 are shorted by solder splashes. In some units pins 26, 27are shorted by solder splashes too.
SonyDXAC70
NO OUTPUT - IC703 DEFECTIVE Found output from IC was high causing unit to go intoprotect.
SonyDTCM100
DISPLAY MALFUNCTION - REPLACED DEFECTIVE D901 Display reacts to level meter and some portions of display arelit dim that should not be on at all.
SonyCDPX777ES
DRAWER JAM WHEN CLOSED OR WILL NOT CLOSE - ALIGN BRKT & PLTE When you closed the door, it closes all the way, than itsnaps closed with a jolt. When you try to open drawer you must push itand once again there is a jolt, then door opens.
SonyCDPH3750
JAMMING DISCS Disc comes off tray and jams mechanism. This problem happenson all 5 disc drawer changers. We already put messages about rough edgesand thick disc within the units but we still have repeat repairs on thisproblem. As we are judged on customer returns,
SonyCDPH3750
DRAWER WILL NOT STAY CLOSED - Q304 AND D327 DUSTY When you attempt to close a drawer the drawer closes to thecenter position and reopens.
SonyCDPH3750
INTERMITTENT DRAWER WILL NOT OPEN - CLEANED S101 Intermittently in shuffle, unit would stop playing disc anddrawers would not respond to open command or load discs. Load discsdisplay no disc and drawers would not open.
SonyCDPH1750
INTERMITTENT DRAWER WILL NOT OPEN - CLEANED S101 Intermittent in shuffle unit would stop playing, disc anddrawers would not respond to open command or load discs. Displays no discand drawers would not open.
SonyCDPC89ES
INTERMITTANT DISC SKIP, TRAY ALWAYS ROTATES - ROLLERS FLAT The unit is continuously spinning the tray or intermittentdisc skip. Troubleshooting, I found that the rollers for the tray wereworn flat. The flat rollers prevent the mech. control from identifyingthe disc location.
SonyCDPC89ES
MECHANICAL NOISE DURING OPEN/CLOSE/DISC SKIP - ADJ BRACKET When units press open/close or disc skips it would make aclick click mechanical noise. As soon as I took the cover off, I saw thatthe bracket (press pulley) was set too low. When the tray turned, thebracket and tray contacted each other.
SonyCDPC500
CONSTANT SLED MOTOR MOVEMENT - RESOLDERED CN1001 Sled motor continues to try to move sled in, switch closed.Disc tray may not open.
SonyCDPC435
UNIT HAD POWER BUT WAS INOPERATIVE - CN801 MAKNG BAD CONTACT Unit had power but was inoperative.
SonyCDPC345
NO PART # FOR FRONT FOOT - P/N IS X49445291 There is no part number for the front foot of the CDPC345.Part X49435101 is (CDPC235) the front panel assy which appears to comewith the front foot. If we order X49435101 we get the front panel for theCDPC235. There is not part # for the front panel of


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.