Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por:![]() |
---|---|---|---|---|---|
Sony | CFD610 | DISC JAM MECHANISM | Fingers on the disc case (ref 269) warp causing a disc to jamthe mech. | ||
Sony | XRU800 | SWITCHING NOISE FROM SPEAKERS WHILE VOLUME IS BEING CHANGED | While the volume is being raised or lowered, switching noisemay be heard from the speakers, especially if high power amps or highefficiency speakers are being used. | ||
Sony | XRU800 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-2) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRU700 | SWITCHING NOISE FROM SPEAKERS WHILE VOLUME IS BEING CHANGED | While the volume is being raised or lowered, switching noisemay be heard from the speakers, especially if high power amps or highefficiency speakers are being used. | ||
Sony | XRU700 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-2) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRU660 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-3) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRU550 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-3) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRU500 | SWITCHING NOISE FROM SPEAKERS WHILE VOLUME IS BEING CHANGED | While the volume is being raised or lowered, switching noisemay be heard from the speakers, especially if high power amps or highefficiency speakers are being used. | ||
Sony | XRU500 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-2) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRU330 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-0) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRU330 | FACE PANEL DOESN'T LIGHT UP (REPLACED LOCK ASSY, REF. 2) | Replaced the lock assy. | ||
Sony | XRU220 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-0) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRU220 | NO POWER (FOUND OPEN TRACE BETWEEN Q117 EMITTER & CNP201 -2) | Unit had no display cannot turn on. No function at all.Checked all B+. Found Q117 E gets 10.5 v. but CNP201 pin 2 is 0v. Foundpattern foil on main PCB broken. | ||
Sony | XRU110 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-4) | It may be difficult to repair the display MCB without using anextension cable. | ||
Sony | XRC410 | EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-8) | It may be difficult to repair the display MCB without using anextension cable. |