Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Amstrad | CTV2200 | Tripping. | C845 ( 4.7u f , 250v ) s/c. | ||
Amstrad | CTV2200 | Self destructs | Caused by dry joints line dr tfmr T801 (Blows Q501, Q802, Q503) | ||
Amstrad | CTV2200 | Low & distorted sound | R313 ( 100ohm ) o/c. | ||
Amstrad | CTV2200 | Int trip off & shut down | Loptx arcing (seen in dark) | ||
Amstrad | CTV2200 | Frame Jitter Or Rolling On Channel Change | Adjust Vertical Hold Control To Centre Of Track | ||
Amstrad | CTV2200 | Frame jitter or roll on channel change. | Set Vertical hold to centre | ||
Amstrad | CTV2200 | Frame collapse | D809 O/C ( DFA056 ) , IC801 ( TDA356 ) TDA3652 | ||
Amstrad | CTV2200 | Field jitter/rolling | C814 470µ 35v | ||
Amstrad | CTV2200 | Field jitter pic rolls int | Replace C814 ( 470uF ) 35V | ||
Amstrad | CTV2200 | Field cramp at top | C812 18n 160v | ||
Amstrad | CTV2200 | Field collapse | R838 10R safety res o/c | ||
Amstrad | CTV2200 | Field collapse | C828 100µ 35v & check IC801 | ||
Amstrad | CTV2200 | Distorted sound | R313 100R | ||
Amstrad | CTV2200 | Dead. | Q501 , Q802 , Q503 caused by drys on transformer T801. | ||
Amstrad | CTV2200 | Dead. | R814 ( 27ohm , 20w ) , fuse , chopper tran , C845 4.7uf |