Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | TCK717ES | UNIT NOT WORKING - REPLACE DEFECTIVE Q808 | Q808 defective, only 8v dc instead of 12v supply to M1053. | ||
Sony | TCK71 | OPEN SOLENOID | The head on this unit would not pull up into the playposition. We found the solenoid to be open. | ||
Sony | TCK71 | CAPSTAN BASE ASSY | This unit ocassionally skews. We found that the left pin onthe capstan base assy was loose. | ||