Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | SLV585HF | CHARACTERS SHIFTED TOO FAR TO THE RIGHT: C625 MA-82 BOARD | The characters were shifted too far to the right whenever avalid video signal was present. The blue screen menu characters wereproperly centered. | ||
Sony | SLV585HF | INTERMITTENT HI-FI PB: DRUM ASSEMBLY. | Customer complained of intermittent Hi-Fi pb on movies andself recordings. Svcr cleaned and adj tape path no help. On RF waveform,one channel was low, so he changed heads, no help. | ||
Sony | SLV585HF | DOES NOT SWITCH FROM VTR TO TUNER- REPLACE RFU001 ON MA82 BD | While using the VCR, if you want to switch to tuner, pictureappears snowy. You have to turn power Off, and turn it back On. Then youwill have a clear picture. | ||
Sony | SLV585HF | DEAD - REPLACE TIMER/CONTROL IC801 MF-122 BOARD. | Unit dead. There is no display and no clock. Power supply isOK. | ||
Sony | SLV585HF | NO EE OR PLAYBACK VIDEO: RESOLDERED IC004 ON YC112 BOARD. | No EE or playback video | ||
Sony | SLV585HF | TICKING NOISE DURING PLAYBACK: RESET SPRING 224 | During playback there was a faint ticking noise. | ||
Sony | SLV585HF | UNIT LOADS TAPE. NO OTHER FUNCTIONS: IC501 MA82 BOARD | There were no transport functions. The unit would load tapeand display would flash auto tracking. | ||
Sony | SLV585HF | MECHANICAL NOISE IN HIGH SPEED REWIND: PULLEY ASSY REF 309 | Excessive mechanical noise, especially during High SpeedRewind. | ||
Sony | SLV585HF | NO (LEFT) AUDIO ON TUNER | The left channel would not work on tuner, but it would work ontape PB. | ||
Sony | SLV585HF | MECHANICAL NOISE IN CUE/REV/FF/REW: PULLY 309 X37277821 | A mechanical noise during cue/review and ff/rewind sounds asthough the capstan motor is dragging. | ||
Sony | SLV585HF | INTERMITTENT VCR JOG/SHUFFLE CONTROL: CLEAN CN804 MF122 BD | Intermittently, when using jog shuffle to rewind, the unitwill go into fast forward instead. | ||
Sony | SLV585HF | NO DRUM ROTATION. EATS TAPES./ CN007 MD49 BOARD LOOSE. | No drum rotation and it ate the tapes when the tape was loadedand PLAY was hit. | ||
Sony | SLV585HF | VERTICAL BAR DISTORTION: REPLACE THE FULL ERASE HEAD | Vertical bar distortion on the video picture. | ||
Sony | SLV585HF | E-E VID/AUD DISTORTION FROM REW TO STOP MODE-TUNER TU001 | When unit was rewinding and stop was pressed, you would getline in EE video and audio would distort. | ||
Sony | SLV585HF | NO DRUM ROTATION | Drum would not spin. Drum acted as though it had a flat spot. ie: if rotated a few degrees or spun while loading unit would work ok for an instant. |