Dicas Reparação




Modelo - Chassis SLHF300


Pesquisa: SLHF300 Enviar Dica Resolvida
Resultados 35
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonySLHF300
NO HORIZ SYNC IN CUE/REV The unit intermittently would loose horiz. sync in the CUE/REVmodes. We found Q504 to be thermally intermittent which allowed phaseoutput to be mixed in with the C/R adjustment.
SonySLHF300
NO CHANNEL READ OUT When input selector on (tuner), have video and sound but nochannel read out and cannot change channels. When in line/pcm position,channel select lights and can change channels but no tuner video or sound.
SonySLHF300
CREASING OF TAPES Damages tapes at beginning, after the machine stopsautomatically from rewind. This problem occurs often using L750 or L830tapes. -HQ COMMENTS: The problem was resolved by changing the spring to astronger one and roughening the base of the reel where th
SonySLHF300
NO TUNER MEMORY Unit has no memory or loses memory.
SonySLHF300
TAPE CREASING Tape damage at beginning of tape after auto rewind with L-750/L-830 tapes. Tape remains slack after rewind, causing damage when playbutton pressed.
SonySLHF300
LOSS OF TRACKING IN PLAYBACK Servicer complained that unit would loose tracking in playback and tracking control had no effect on pix. Record mode was Ok.Slight leakage was detected on Q5, causing base of Q507 to go high andturn on, putting composite sync on Pin 3 of IC501.
SonySLHF300
TAPE CRINKLES AT START At start of tape, lower edge of tape crinkles for a fewseconds. This is not consistent and happens to various brands of tape(mostly L-750) so tape does not seem to be the fault. -HQ COMMENTS: Please try the Japanese T/N that I faxed to you(BET-855043,
SonySLHF300
TAPE DAMAGE This unit had distorted audio and lower edge of tape waswrinkled. Pinch roller rubber was machined wrong.
SonySLHF300
POOR TAPE PATH This one had poor tape path causing improper tracking. I haveseen an increasing number of new units with poor tape path right out ofthe box.
SonySLHF300
PINCH ROLLER SOLENOID REPLACEMENT Replacement part (identical number) has stop washer onplunger. Washer is too large to allow proper installation of motor andgear assembly.
SonySLHF300
NO PLAY OPERATION Unit would load tape, but no power lamp and when PLAY buttonwas pushed, no tape movement. Drum motor would not turn and neither wouldthe capstan motor, found cold solder joint on CN3/PS-39 board, TerminalNo. 4. This is the 9V supply line.
SonySLHF300
NO OPERATION Betamax would load cassette and tape. PLAY button was pushed,nothing happened. Tape could be unloaded.
SonySLHF300
NO TIMER/CHANNEL SET This unit had no channel display and it was not possible toset the timer mode. We found IC301 Pin 16 to be low. This was caused bya leaky Q305.
SonySLHF300
DRUM SPEED IRREGULARITY IN FAST WIND Drum speed varies when unit is in FF or REW. During normalplay or Beta scan, unit OK. Customers have been complaining because theycan hear the speed vary. Judicious selection of Q503/504 works sometimes. -HQ COMMENTS: The variation of drum speed in t
SonySLHF300
NO POWER Unit would not power up. Replaced IC301 (timer) but IC wouldnot reset, so problem was not resolved.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads