SonyPSFL7II
NO DRAWER TRNASPORT +6V PS DEAD No +6V supply - all others good. Regular circuits ok. Fuselink PS409 opens because of a shorted filter cap. Voltage rating on the100uf caps are 6.3V that leaves a very small difference between Vmax andsupply. If other supplies are found to be shorted
SonyPSFL7II
SHORTED C403 Dead set.
SonyPSFL77
DEFECTIVE SWITCH All functions were inoperative. We found Pin 26/IC201(Sys Con) to be high with the tonearm in the rest position. The metalFINGERS on the tonearm position switch were bent and not making contact.A simple way to confirm a problem with the position switch
SonyPSFL7
PINS OUT OF PLACE The copper sleeves in the P-mount socket were pushed backtoo far to make contact with the pins of the cartridge.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.