Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Daewoo | CP775 | Dead with psu running | No or low line drive at base Q402 line dr - check Trs Q405 2SA854 & Q406 2SC945 for leak | ||
Daewoo | CP775 | Dead - lop tr Q401 2SD1880 s/c | C416 blue disc cap 680pf 2kv s/c. D503 1N4148 s/c; RC527 10R chip res; R503 10k; R409 4k7 were cause of problem | ||
Daewoo | CP760 | pic displaced to left | crack in pin 10 loptx - no fback pulse to line gen AFC loop | ||
Akai | SP7101 | St/by only | Replace C093 sm (on print side) | ||
Akai | CT2867 SP71L | St/by only | C093 or another cap in parallelmarked R093 removing these 2 surface mounted capacitors and cleaning the glue under that had fixed them to the pcb cured the problem | ||
Nokia | SP71D1 Stereo Plus | Não funciona comando nem Keyboard | mod contol painel | Ve 24 =Bc 848 | |
Philips | 54PP700A | SEM SINTONIA. | Verificar cabo de conexäo A402 pino 1 (+130V). * 16Out97 ANC *. | ||
Philips | 54PP700A | QUADRO CINTILANDO COM EXPANSAO "BLOOM". | Verificar integrado IC402 (cold side). * 13Out98 Alan *. | ||
Philips | 53UP72G | VERTICAL FECHANDO INTERMINTENTE. | Verificar soldagem de IC552 e IC550. * 29Ago96 ANC *. | ||
Philips | 53UP72G | TENSOES ABAIXO DO ESPECIFICADO (VO, +B,..) | +15 e 15, verificar IC110 (N5532). * 25Set97 ANC *. | ||
Philips | 53UP72G | TENSAO OSCILANDO (PULSANDO). | Fonte de (+5V STB), possivel curto na linha do +5, ver D305 e D306 com fuga. * 16Ago96 ANC *. Verificar integrado IC401 (6126642). * 25Set97 ANC *. | ||
Philips | 53UP72G | TELA VERDE | R698 aberto. *17Set98 H.Desk* | ||
Philips | 53UP72G | TELA ESCURA "PRETA" (VEJA TAMBEM BRIL4). | Verificar capacitor C618 (.01) com fuga, pino 58 IC600. * 15Ago96 ANC *. Acionado pelo vertical, ver R585 (20k). * 09Out96 ANC *. Resistor R301 (0,27Û) aberto. * 05Nov96 ANC *. Verificar integrado IC600 (TA8845AN). * 27Ago97 ANC *. Caso fi | ||
Philips | 53UP72G | TELA AZUL | Resistor R301 (0,27Û) aberto, ocorre ao ligar e depois a tela fica escura. * 05Nov96 ANC *. Tela AZUL C/DOS e C/SOM, verificar IC304 (placa SSP). *17Set98 H.Desk* | ||
Philips | 53UP72G | SOM APRESENTA APITO OU ZUMBIDO. | Verificar bobina L804. * 05Nov96 ANC *. |