Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sanyo | CTP7132 80P | TRIPS SLOWLY | C312 10uF | ||
Sanyo | CTP7132 80P | LINE OP TR SC | RESOLDER HEATSINK IF FAULT REOCCURS REPLACE D305 IN POWER SUPPLY AND POSSIBLY LOPT | ||
Sanyo | CTP7132 80P | East west - fault R4012 burnt. | R4012 ( 2.2R ) Q4005 s/c , R4011 burnt , EW coil L4001 s/c. | ||
Sanyo | CTP7132 80P | Dead with s/c LOP TR | Check connection to heatsink plate on main pcb & D305 zener in error detector cct - causing HT to rise | ||
Sanyo | CTP7132 80P | Line OP transistor s/c. | RESOLDER HEATSINK IF FAULT REOCCURS REPLACE D305 IN POWER SUPPLY AND POSSIBLY LOPT | ||
Sanyo | CTP7132 | No sound | C321 1000uF 35v OC | ||
Sanyo | CTP7132 | Line TR s/c | C312 ( 10uF ) o/c | ||
Sanyo | CTP7132 | Field collapse | C445 ( 2 , 200uF ) | ||
Sanyo | CTP7131 | DEAD BU208 SC . CHECK HT , IF HIGHER THAN 145v | C314 220uF 25v | ||
Sanyo | CEP7100 | Field foldover at top | C440 4µ7 250v | ||
Sanyo | CEP7100 | FIELD FOLDOVER | C440 4u7 250v | ||
Samsung | P72 CI6229T | int. dead or when warm wont come on from stby | C806 100uF 25V (pin 9 TDA4601) | ||
Samsung | P72 CI6229T | frame collapse | C808 goes faulty and destroys IC301 TDA3654 | ||
Samsung | P72 | buzzes then off | C806 100µ 25v leaky connected to pin 9 TDA4601 | ||
Samsung | P72 | buzzes then off | C806 100µ 25v leaky connected to pin 9 TDA4601 |