Pesquisa: NP84CQ HITACHI Enviar Dica Resolvida
Resultados 38
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Hitachi CPT1446R NP84CQ
H.T fluctuations, picture becomes half white and half black. H.T varies from about 80V to 110VReplace ZD902. It's a 10V zener diode
HitachiNP84CQ/2
NO PIC + SCREAMSLOPT + TRANSISTOR SC
HitachiNP84CQ/2
line - tear - pulling & drift.C214 ( 470uf ) of pin 7 of IC201
HitachiNP84CQ/2
Int blowinf fuse.TH901 posistor.
HitachiNP84CQ/2
Distorted sound.R423 ( 56R ) high in value.
HitachiNP84CQ/2
Dead.STR4211 IC901 power supply IC s/c , also change2.7v zenor
HitachiNP84CQ/2
DEAD BUZZES , ZD953 S/CC908 4u7 160v
HitachiNP84CQ/2
Channel display no other functionsReplace Q902
HitachiNP84CQ
Top of the picture blanked outC905 o/c 100mfd 200v (next to tuner)
HitachiNP84CQ
The picture would roll. EHT trip thyristor operatiR908 in the regulator circuit had risen in value from 22k .The fault could also occur with Models CPT1444 and CPT1446.
HitachiNP84CQ
Stuck in standby.1.6a fuse on L/H side main PCB.
HitachiNP84CQ
Stuck in standby.R908 22k HIGH
HitachiNP84CQ
Partial field collapseC603 47µ 150v in field o/p cct
HitachiNP84CQ
NO SOUNDTDA4503
HitachiNP84CQ
No sigs - just snowNo 12v to tuner - crack in print by R222 AGC control


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.