Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | KV1953RS | INTERMITTENT SHUT OFF, REPLACED Q602 | Found Q602 leakey. | ||
Sony | KV1953RS | DARK PICTURE, REPLACE C548 | Dark picture, sometimes blowing fuse and regulator. Fivecases have come to our attention of this problem, which is caused by C548being shorted or leaky. Attached are samples for evaluation. | ||
Sony | KV1953RS | BAD RECEPTION, REPLACE BAND SW IC002 | This unit did not have the proper band switching voltages.We found the input to IC002 correct but the output was incorrect. |