SonyKV1510
HORIZONTAL OSCILLATOR NOT RUNNING Dead set. Minimal current being drawn from regulated powersupply. Vcc present at horizontal output transistor, but horizontaloscillator not running. Externally power horizontal oscillator, and bringset up on variac set works ok.
SonyKV1510
PART'S COMPATIBILITY When subbing the 1-463-109-00 tuner with the 1-463-132-00,the channel indicator numbers go down when they should go up and viceversa. -HQ COMMENTS: Replace the original tuner. In addition you have to orderDIAL DRUMS from KV-1511: S/M Page 32, P/N 4-31
SonyKV1510
PICTURE DISTORTION This unit had bright bars at the left and right hand side -about 1 wide. The balance of the picture was close to normal althoughlacking detail. We found C532 to have opened up. This filters the B+ tothe video outputs.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.