Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | KP5040 | DEAD, REPLACED CX171, Q5521, Q5522 | Set would not turn on. Servicer found CX171 defective whichis believed to have caused Q5521 and Q5522 to short, fuse found defective. | ||
Sony | KP5040 | TEST SIGNAL INTERFERENCE, INSTALL CAP | Cross hatch bleed through on KP-5040. Bar pattern when view-ing a weak incoming active channel. This condition sometimes can be moreeasily observed by setting the TV line switch S907 to the line position.In this configuration a faint bar can be seen ru | ||
Sony | KP5040 | PICTURE DISTORTION (OSCILLATION), ADD CAP | Oscillation (snivet) down center of screen noticed on set inclose proximity. Also had white horizontal lines similar to ignitionnoise. | ||
Sony | KP5040 | COLOR DISTORTION, REPLACED IC3301 AND CRT | Red very weak, unable to set gray scale. Bias wrong onpicture tube. Changed IC3301 corrected bias, but red picture tube bad,had to change it too. | ||
Sony | KP5040 | INCORRECT MECHANICAL FUNCTION, USE OF LOCTITE | When unit was turned on the mirror door would extend about2/3 of the way out and start clicking. The motor would continue to runand not shut off. Disassembly revealed the retaining nut on the driveshaft had worked loose allowing the left hand side door |