SonyKP5040
DEAD, REPLACED CX171, Q5521, Q5522 Set would not turn on. Servicer found CX171 defective whichis believed to have caused Q5521 and Q5522 to short, fuse found defective.
SonyKP5040
TEST SIGNAL INTERFERENCE, INSTALL CAP Cross hatch bleed through on KP-5040. Bar pattern when view-ing a weak incoming active channel. This condition sometimes can be moreeasily observed by setting the TV line switch S907 to the line position.In this configuration a faint bar can be seen ru
SonyKP5040
PICTURE DISTORTION (OSCILLATION), ADD CAP Oscillation (snivet) down center of screen noticed on set inclose proximity. Also had white horizontal lines similar to ignitionnoise.
SonyKP5040
COLOR DISTORTION, REPLACED IC3301 AND CRT Red very weak, unable to set gray scale. Bias wrong onpicture tube. Changed IC3301 corrected bias, but red picture tube bad,had to change it too.
SonyKP5040
INCORRECT MECHANICAL FUNCTION, USE OF LOCTITE When unit was turned on the mirror door would extend about2/3 of the way out and start clicking. The motor would continue to runand not shut off. Disassembly revealed the retaining nut on the driveshaft had worked loose allowing the left hand side door


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.