SintomaCausaSoluçãoPor:
SonyKP5000
NO CONTROL OF HOR. KEYS OR HORIZONTAL SIZE, REPLACED D-5303 Does not control horizontal keys and horizontal size.
SonyKP5000
TUNER WILL NOT LOCK IN ON ANY CHANNEL, REPLACED C208 Tuner would not lock in on any channel. Forced tuner intolocking up on a station and picture had very weak video information.Drive IC-2202 pin 4 (AFT Detect) pin, had 12V DC, and pins 1, 2, 3 had6VDC each on them.
SonyKP5000
AUDIO OUTPUT TRANSISTORS Audio output transistors get defective every couple of months.Replacing the (Q) board does not help.
SonyKP5000
VERTICAL PROBLEM WHEN WATCHING COPY GUARDED TAPES When playing back some copyguarded VHS tapes the KP5000 willloose vert. lock. Approx. every 45 secs, it pulls down about 3/4 inchesthen will lock back in. No vert. jitter. -HQ COMMENTS: Copyguarded tapes can and often do cause problems. Thesolution w
SonyKP5000
OVERALL GREEN TINT ON UPPER 1/3RD OF PROJECTION SCREEN The upper 1/3 of the screen has an overall green tint to thepicture/program material. I have also seen 2 other KP-5000 projectionsystems recently with the identical problem. -HQ COMMENTS: Please clean CRT surface. It will be necessary to removelens as
SonyKP5000
INCORRECT P/N FOR C5304 IN S/M, CORRECT P/N IS 1-130-121-00 Part number listed for above capacitors shows 1-129-935-00.This part number is for a 500pF 1.5KV capacitor. The correct part numberfor the capacitors is 1-130-121-00. -HQ COMMENTS: We sent the report to correct service manual.
SonyKP5000
PROJECTION TV VIDEO SCREEN CLEANER When applied, the video screen cleaner left streaks on thescreen which could not be removed. Also burnt and irritated his hands.
SonyKP5000
NO CHANNEL LOCK, REPLACED Q2207, Q2208 When programming the set, tuner would not stop on thechannels. We found a constant H (12V) at Pin 4 of IC2202 (Neon Drive).We traced the problem to a leaky Q2207/Q2208 sync detect/clamp circuit.
SonyKP5000
CONVERGENCE CHANGE, REPLACED GREEN CRT When setting unit up for convergence by placing hatch patternon screen, the set would set up nicely. Then when switching the crosshatch off, the pix looked severely mis-converged. Closer inspectionrevealed that only the green was mis-converged and in v
SonyKP5000
COLOR DISTORTION This unit would change the width of the green raster by twoinches when going from min to max brightness. The unit would alsoconverge OK on internal generator and then when it went back to video, theunit would be misconverged but would still check OK on
SonyKP5000
OUT OF CONVERGENCE Green would go in and out of convergence as the green tube wasarcing. Also brightness level change would affect size of green pictureproducing misconvergence effect.
SonyKP5000
PICTURE DISTORTION, LOOSE SCREW ON HOR DRIVE TRANS. Q5104 Intermittent horizontal sweep problem causes sweep to collapseand burn a vertical line in the three picture tubes.
SonyKP5000
DEAD, REPLACED MICA SPACER UNDER VERT OUTPUT TRANSISTOR 2.5 amp fuse on B+ line would blow every 7 to 10 days.Replacement of the fuse restored operation and hours of testing providedno clue to problem causing fuse to open. By by-passing the relay witha jumper and using a variac, increasing AC input to 130V A
SonyKP5000
POOR PURITY Color purity problems around edge of picture. Problem wascaused by flaking of phosphor edges on all three CRTs.
SonyKP5000
INCORRECT FUNCTION FOR TUNING, Q2211 LEAKY During programming unit would not stop on active channels inone direction from low to high.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.