Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Ferguson | ICC7 | int black & white lines | dry joints esp CS25 1µ in IF module | ||
Ferguson | ICC7 | Field IC replacement | Replaced by STV9379F & 3k9 between pins 2 & 7, 2v1 zener between pin7(+) & (-ve) to chassis (IC MUST have suffix "F") - If not you get lack of height & blows line dr tr & RP52 safety res | ||
Ferguson | ICC7 | Field foldover at bottom | CF84 1µ (in front of field coils plug) | ||
Ferguson | ICC7 | Field foldover : Reduced scan | RF23 o/c Print o/c at pin 12 LOPT RF07 ( 1M5ohm ) RF21 ( 0.68ohm ) DL09 ( BA157 ) DF17 s/c | ||
Ferguson | ICC7 | FIELD FOLDOVER | USUALLY AFTER TDA8178F FIELD IC IC CHANGED THIS IS MARKED AS A LINK J238 AND NOT SHOWN IN MANUAL. PT No. Ferguson 41081600 | ||
Ferguson | ICC7 | Field collapse Screen blanked out May go into StBy | Check RV72 ( 22ohm ) RL11 ( 15ohm ) RF07 ( 1M5ohm ) DF16 ( BA1257 ) DL11 ( BA157 ) | ||
Ferguson | ICC7 | Field collapse | DF16 BA157 | ||
Ferguson | ICC7 | Field collapse | Check for cracks in print between pin 5 IF01 & pin 2 BF01 Scan coil plug | ||
Ferguson | ICC7 | Exitting factory mode | switch off set, hold in both volume buttons on the set whilst switching back on | ||
Ferguson | ICC7 | Dead standby LED on. | CHECK LINE DRIVE O/P.CHECK PIN 20 IRO1 , SHOULD BE HIGH TO START IVO1 | ||
Ferguson | ICC7 | DEAD NOT TRIPPING | RP62 OR1 DL09 SC | ||
Ferguson | ICC7 | Dead No LED | Check V at pin 16 TEA2261 if low 1.6V replace DP28 ( BA157 ) | ||
Ferguson | ICC7 | DEAD LED LIGHTS FOR 8-10 SECS THEN GOES OUT | SCOPE LINE DRIVE AT PIN 39 TA8659 , IF OK , CHECK at base Tl17 ALSO CHECK DF16 , DL18 | ||
Ferguson | ICC7 | Dead HT present | 3300µ 35v cap behind loptx leaked & corroded adj track | ||
Ferguson | ICC7 | DEAD HT - LINE DRIVE RISES - DIES | CHECK LINE DRIVE AMPLITUDE |