Dicas Reparação





Pesquisa: ICC6

Resultados 28

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SABA, NORDMEND, FERGUSONICC6
ICC6
Imagem desloca-se até ficar com uma barra lateralTransistor TV71 (BC857) SMD
ThornICC6 C51TNo pic - blank raster with fb lines - sound ok; OSD OK if A1 advancedReplace TV92 (BC858B) surface mounted transistor
Saba6317 ICC6No soundReplace TV86 SMD transistor.
Ferguson ICC6Very dark picture (All Cathodes measured 190voltsTB11 (BC557 on CRT Base)
FergusonICC6 C51F Service mode enteringPut the TV into stby.then switch off at mains... wait until the stby led goes completely out. switch on at the mains whilst holding down the Blue fastext key on the r/c. let the key go when TV comes on . the n press the Blue key again and a menu will come on screen. Vol +/- moves menu sideways. the Blue key moves down the menu. vol +/- alters the values...scroll all the way down the menu to find "store" to keep changes.remove mains to get out of menu."
FergusonICC6 C51F Bright raster with fb lines aft LOPTx replacementRL11 (15r fusible) immediately behind the lopt
FergusonICC6 C51FLOPTx arcingReplace LOPTx HR7269 resulted in 2 x RGB o/p Trs damaged BF871 & G2 cap 10,000pF 3kv leaky & TB11 BC557C on crt base
FergusonICC6When playing MACRO encoded tapes AV time constantReplace CV86 with ( 8.2nF ) & RV64 with ( 12K ) & RV66 with ( 15K )
FergusonICC6Trips 9 times then deadTL90 BC848B & TF01 BC848B in beam lim faulty tho check ok out of cct
FergusonICC6St/by only - LED flashesDis pin 4 from reg IC TDA8139 (Dis prot) brought up blank raster with no OSD, fitted new proc original is type ST6393B1/ZM, but the Seme CD advises using ST6397BB1& replace TDA8139 reg which was also faulty
FergusonICC6sizzling sound from loptLOPT replaced
FergusonICC6Removing child lock1 switch to standby 2 switch off with mains and let light go out 3 switch on mains while holding standby on remote for 6 secs 4 a red key shows it is locked ,toggle on/off with +/- buttons on remote
FergusonICC6No video o/p intermitTV92 BC858B sm
FergusonICC6No raster until A1's advanced then blankdry joints around loptx
FergusonICC6No G2 voltsC814



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads