SonyCCDF77
NOISE DISTORTION IN PLAY. MAINLY ON STRAIGHT LINES Unit came in for a click in playback. There was a fuzzypicture like 1 head bad. Tapped on the head amp with a woodenscrewdriver handle. Distortion would come and go. Last time thishappened, I replaced the head amp. This time I found that CH1 EQ(Freq
SonyCCDF77
DISTORTED LUMA E-E, C717 ON CT-21. Distorted picture in E to E. Checked video out of cam headand was clean, but had spikes after CT-21. Followed (Y) signal in toCT-21 circuit and showed spikes after C717 coupling cap.
SonyCCDF70
CAMERA MODE, VIDEO HAS STREAKS AND FLARES IN HIGH LITE AREAS When camera is directed towards high brightness or brightlight, shows vertical streaks in video. These streaks off of main sourceof brightness in picture can start at top of picture to bottom or smaller. Attempted to adjust V-sub but voltage nor picture
SonyWMAF79
CHASSIS ASSY DIFFERENT FROM CHASSIS IN DEFECTIVE UNIT. The chassis (A3163146A) is different from the chassis insidethe defective unit. There are two different chassis with the same partnumber. The metallic lever on the chassis is bent differently and has adifferent shape. -HQ COMMENTS: KCPS faxed WRPC and
SonyCCDF77
WINDSCREEN PART NUMBER/USE X-253-672-01 FPR #L1005 states windscreen does not have a part number,this is incorrect. The windscreen is available-part number is X25367201.It is not listed in Service Manuals for CCDF77.
SonyCCDF77
WILL NOT LOAD TAPES/CHECK PIN 12 IC503 SS100 Would not load tape and trouble indicator came on. Found novcc at pin 12 of IC503. Feed through was open near C513- vcc line.
SonyICF7600D
PART VALUE IN UNIT DOESN'T MATCH SCHEMATIC AND SHORTED C65 Schematic says R67 is 1.5K but, I found a factory installed100 ohms resistor in its place. Also C65 was shorted and this was causingno AM reception because the drain of Q11 was being pulled low through T9. Possibly the bad cap was caused by the wrong va
SonyCCDF77
INTERMITTENT E TO E SOUND/E TO E COLOR/CHECK W502 FU-72 Checked chroma in at W701 Pin 3. OK. Found Chroma signalgoing into CT21 board, W701 pin 4. No signal coming out of W704 pin 5.
SonyCCDF77
LCD ON SIDE DOES NOT LIGHT/CHECK PAGE D ADDRESS 59=7A LCD display on the side of the camera does not light up. Allbutton, i.e., manual focus, White Balance, etc. operate normally.Swapping whole side covers (w/PCBs) with known good unit, does not fix theproblem. Had four (4) units with this problem.
SonyWMF76
TAPE SPEED TOO FAST AND AUDIO IS MUTED - CHANGE MOTOR M-301 After pressing play the tape was moving very fast and therewas no audio. Going for the muted audio first, I found pin 10 of IC303(headphone drive) was low from Q309 being turned on. Following it back toQ602, both sections were turned off causing this mut
SonyCCDF77
NO LUMA IN CAMERA MODE/ C401 There was no luma in camera mode. I traced good luma signalto pin 33 of IC-401. I found YH CLP level at pin 39 to be 4.2v when itshould be 3.2V.
SonyCCDF77
NO RECORD/REPLACE C-911 There had been a complaint of no recording. The drum wasrunning at high speed. An open cap caused improper VS voltage to beapplied to drum motor. -HQ COMMENTS: C-911 is connected between Q-901 emitter (Drum VS Reg) andground.
SonyWMAF79
NO REFERENCE NUMBER- V KNOB/ MEGABASS KNOB Page 23 in WMAF79 manual shows a breakdown of mid half ofunit. The volume cap, screw, and O ring are given reference numbers butthe knob is not.
SonyCCDF77
AVAIABILTY OF VK-4 BOARD (COMPLETE)
SonySRF75
NO POWER - REPLACE SLIDER, P/N 3-890-622-01 Slider broken, resulting in no power.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.