Dicas Reparação




Modelo - Chassis EUROMONO


Pesquisa: EUROMONO Enviar Dica Resolvida
Resultados 12
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Salora21S5EE EUROMONO2
No start up - all psu volts present & LED lightsOC44 (1000uF 16V), a good resorder on line drive circuit & 5C34 (470uF 16V) - 5C36 (220uF 35V) replaced
Nokia 6332 EUROMONO 110' Chassis
Random thick black spots in picture, varying in shape and size according to picture contrast and brightness.Replace SMD transistor 4T06 (BC858) next to U4647 chip.
Nokia 6332 EUROMONO 110' Chassis
Random thick black spots in picture, varying in shape and size according to picture contrast and brightness.Replace SMD transistor 4T06 (BC858) next to U4647 chip.
NokiaEUROMONO 2 6332
Field - 3 coloured lines at top of screen6D04 1N4002 leaky between pins 2 & 6 TDA8170 FOP chip
NokiaEUROMONO
Dead - EHT starts to rise at sw on, no ledOC44 1000µ16v in 8v supply
Nokia7142 EUROMONO 2
Flyback lines after fitting Konig FAT 30091 LOPTx1) adjust H sync 2) fit 1nF 5C40 3) remove 5C17 (12pF) & fit 22K res in 5C17's place
Nokia21S4C EUROMONO
Sigs intOC38 1000uF 16V, OC44 1000uF 16V and OC40 100uF 25V
ITTFX5532 EUROMONO
Lack of height from cold ( about 1 inch ) , clearing6C10 ( 220UF , 35V ) in the flyback boost voltage generator network associated with the TDA8170 field output chip 6IC02.
ITTEUROMONO 2
Lack of height from cold6C10 220µ 35v
ITTEUROMONO
No colour.13IC04 ( Tvp02066 Em0302 ) Pt No.3779-12-24 )
ITTEUROMONO
Int picture floods red with flyback lines.IC1002 ( TEA5101A ) on CRT base.
ITTEUROMONO
Blank raster with flyback lines.No 185v to CRT base , 5R56 ( 4.7R saftet ) o/c.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads