Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Aiwa | VXD1420 | Pin code removal | Enter wrong no 3 x, then press Vol- on set & "7" on R/C for 5 secs when "protected" appears | ||
Microtec 14" NE Digital | JD144k | Sem controle de brilho | R437 (220K) aberto | ||
Microtec 14" NE Digital | JD144k | Sem controle de brilho | R437 (220K) aberto | ||
Microtec 14" NE Digital | JD144k | Sem controle de brilho | R437 (220K) aberto | ||
Sony | D143 | #S SWITCHED FOR M901/902 IN MANUAL | Reference numbers on page 31 of service manual for motorsswitched. M901/902 in break out are switched. | ||
Sony | D143 | STATIC NOISE HEARD IN AUDIO OUT - REPLACE IC601 (875929718) | Static or noise heard in audio out. | ||
Sony | D141 | UNIT POWERS UP THEN SHUTS DOWN WITHIN 2 SECONDS | Unit would power up but shuts down within 2 seconds. | ||
Sony | D141 | NO DISPLAY - REPLACE IC801 (8-759-326-68) | No display. Unit functions ok. IC801 syscon, putting outabnormal/distorted pulses. All B+ and must haves read ok. | ||
Sony | D141 | #S SWITCHED FOR M901/902 IN MANUAL | Reference numbers on page 31 of service manual for motorsswitched. M901/902 in break out are switched. | ||
Sony | D141 | STATIC NOISE HEARD IN AUDIO OUT - REPLACE IC601 (875929718) | Static or noise heard in audio out. | ||
Sony | CPD1425 | PART NUMBER CORRECTION | Service Bulletin C/P0100 has VR307 listed as T99857471 andalso as T99858191. Both part numbers are incorrect, I believe correctpart number is T99858181. -HQ COMMENT Check SB CSI-111 No. 100R1. This was issued in Jan.1996 with updated replacement p | ||
Sony | D143 | UNIT WON'T READ A DISC | Disc table won't spin and unit won't read disc. | ||
Sony | D143 | UNIT POWERS UP THEN SHUTS DOWN WITHIN 2 SECONDS | Unit would power up but shuts down within 2 seconds. | ||
Sony | CPD1425 | H. POSITION CONTROL VR DEFECTIVE | Picture shifts horizontally. | ||
Sony | CPD1425 | BROKEN MAIN BOARD | Dead, Main Board broken near flyback transformer. Damagecaused by hard plastic support bearing against weak spot on board.Unit bumped in normal handling causes a break in Main PCB. |