GRUNDIGCUC3400Linhas de retorno e excesso de brilhoVerificar Zener D707 (4,7V), C711, C731
GRUNDIGCUC3400Inop. Queima Fusivel de 800mAVerificar C667(2u2), C653(4n7), D663, D664
GrundigCh CUC3400Sem CorPot. Aj. R2533 470R
GrundigCh CUC3400Queima T661 BUT11A/12AC667 2.2uF 450V (nos Mod que é Electrolitico)
GRUNDIGCUC3400Tecla P+ do painel não funciona, não entra em stand-by.Trocar o interruptor on/off.
GrundigCUC3400Tripping comes on if adj line frequency down.C653 ( 4.7u f )
GrundigCUC3400trippingset ht pot R637
GrundigCUC3400Startup - No s/up - ticking from transformer.C653 ( 4.7nf ) connected to pin 15 of IC.
GrundigCUC3400Poor R/C responseR1212 33R missing in sensor pcb
GrundigCUC3400Poor purity & focus.C433 ( 1 , 000uf , 25v )
GrundigCUC3400No start up with tickingHT at chopper coll - C653 4n7 connected to pin 15 power chip u/s
GrundigCUC3400No start up - ticksC653 4n7 connected to pin 15 of power chip u/s
GrundigCUC3400No soundC266 1000µ 25v s/c; R367 8R2 safety res o/c
GrundigCUC3400No chan change when cold - display changes ok tho'Dry joint pin 15 tuner/if socket
GrundigCUC3400Int or perm tripping - ok on dummy loadTiming cap C653 4n7



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.