Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Grundig | CUC2401 | Trips at sw on | L519 shorted turns | ||
Grundig | CUC2401 | Tripping - at switch on. | R637 1k control. | ||
Grundig | CUC2401 | Tripping - at switch on - may come on. | C661 ( 7u f , 25v ) | ||
Grundig | CUC2401 | Switching to standby - my take days. | Tripler. | ||
Grundig | CUC2401 | Startup - failure to start intermittent. | Set HT R637 ( 1k ) may ch Ok , LOPTX if going off af few mins | ||
Grundig | CUC2401 | Standby - intermittent shut down. | Set HT control R637 ( 1k ) may check Ok. | ||
Grundig | CUC2401 | Sound - mutes on video rec playback. | Mod ABL module. | ||
Grundig | CUC2401 | SET GOES TO STBY VERY INT | TRIPLER US | ||
Grundig | CUC2401 | No sound or - Picture - intermittent. | Suspect the set-EHT control ( especially if made by Preh. | ||
Grundig | CUC2401 | No sound | Could be TDA2595, TDA130 or SDA2011-A003 micro | ||
Grundig | CUC2401 | No sound | TBA130 chip not working due to C2276 470µ s/c | ||
Grundig | CUC2401 | No sound | C2276 ( 470uf ) s/c. | ||
Grundig | CUC2401 | No raster - line collapse | LOPTx o/c | ||
Grundig | CUC2401 | No pic - sound ok | No vid o/p pin 8 TDA3566 - Tr2523 BC548C s/c | ||
Grundig | CUC2401 | No pic - blanked out | Field only half normal height due to supply only 10v to field chip - R525 0R33 hi res |