Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Grundig | CUC220 | Horizontal shaking. | Tuner/IF dry joints , check the electrolytics with freezer | ||
Grundig | CUC220 | Goes straight off at sw on | odd characters in display - HT = 180v (109v) HT pot int | ||
Grundig | CUC220 | Frame distortion. | IC TDA1770 if used , D2761 ( SKE4G1/04 ) , R2761 ( 6.8ohm , .75W ) | ||
Grundig | CUC220 | Frame collapse. | R2779 ( 18k ) o/c remove to check. | ||
Grundig | CUC220 | Excess col & brightness when heated | OK when Txt pcb dis'd - left it this way | ||
Grundig | CUC220 | Display - intermittent incorrect channel disp | IC663 ( 5v reg ) | ||
Grundig | CUC220 | Dead - intermittent. | R646 ( 270k ) on PSU. |