Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Grundig | CUC120 | Startup - takes a long time to come on. | C626 reservoir cap. | ||
Grundig | CUC120 | Startup - no start up. | IC TDA4600 plus check drys on L631 off base of chopper Tx. | ||
Grundig | CUC120 | No sound | C2408 1000µ s/c; R2408 o/c 3R9 on audio board | ||
Grundig | CUC120 | No picture - EHT & sound ok. | D2764 ( SKE2F1 ) o/c. | ||
Grundig | CUC120 | No luminace. | D2536 ( IN4148 ) leaky. | ||
Grundig | CUC120 | No cold start | C626 reservoir cap o/c | ||
Grundig | CUC120 | Lack of frame at bottom when cold. | C2768 ( 100uf ) on deflection PCB. | ||
Grundig | CUC120 | Intermittent shut down. | IC TDA4600 plus check drys on L631 off base of chopper Tx. | ||
Grundig | CUC120 | Intermittent shut down. | Dry joints on L631 off base of chopper Tx. | ||
Grundig | CUC120 | Intermittent going into standby. | Change R647 to ceramic. | ||
Grundig | CUC120 | Interference at sides. | IC TDA2595 sync/line osc IC. | ||
Grundig | CUC120 | Int luminance | C2527 0µ1 faulty | ||
Grundig | CUC120 | Frame distortion. | IC TDA1770 if used , D2761 ( SKE4G1/04 ) , R2761 ( 6.8ohm , .75W ) | ||
Grundig | CUC120 | Frame collapse - sound ok. | D2764 ( SKE2F1 ) o/c. | ||
Grundig | CUC120 | FIELD FAULTS | C2768 D2761 R2761 6R8 PRESETS OR TDA1770 |