GrundigCUC7350
Width varies with pic content - HT varies between 119-129vR60027 0R56 in curr sensing network - also check R60028 in parallel - values vary with screen size
GrundigCUC7350
Unstable HTR60028 0R68 o/c - check it out of cct!
GrundigCUC7350
TrippingR60027/28 0R46 gone hi res
GrundigCUC7350
St/by onlyLM317T reg s/c by its heatsink clip
GrundigCUC7350
No soundcheck sm trs to left of audio IC - mute sound in st/by & when told by micro - BC848C faulty in this case
GrundigCUC7350
No HT controlHT pot R60027 increased in value from 0R68 to 1R5
GrundigCUC7350
mains fuse o/c, BUZ chopper tr s/cdry joint C60029 470pf 1.6Kv also check D60011-14 & D60023/4 rects
GrundigCUC7350
Int start upC60031 100µ 35v in psu
GrundigCUC7350
Dead IRFBC40 chopper MOSFET failureDry joints C60029 470pf. Check R60027/28 0R46, R60022 10R, D6011-14 D60023-24 1N4007
GrundigCUC7350
Dead - Chopper FET & 2 rect diodes s/cdry joint on C600 - blew again later due to arcing between FET & heatsink
GrundigCUC7350
Dead - 2.5A fuse blackenedT60020 IRFBC40 chopper tr s/c; D60013 1N4007 mains rect s/c; C60029 dry joints; R60023 1N4003 s/c; R60027 0R56 o/c
GrundigCUC7350
DeadChopper FET & control IC partial cure but all volts low until R60027/8 0R56 1w reistors replaced
GrundigCUC7350
"E" instead of "OK" shows when storingSw on with "Prog -" button depressed to clear "fault"
GrundigCUC731KT
No start upD633 1N4935 s/c
GrundigCUC7306
Auto tune problemsif auto tune used it defaults to wrong tv standard be aware!


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.