Dicas Reparação GRUNDIG




Modelo - Chassis CUC


Pesquisa: CUC GRUNDIG Enviar Dica Resolvida
Resultados 536
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
GrundigCUC740
Pulling/rolling with weak syncreplace 2 x 1µ caps & 1 x 10µ cap in IF module
GrundigCUC740
Pulling/Rolling - weak sync2 x 1µ & 1 10µ cap in IF module
GrundigCUC740
No adj of vol,col,contrast etcIC2335 MC144111 inside IF/Tuner can
GrundigCUC740
lines across screen - no soundadj R2741 on Ablenkung pcb
GrundigCUC740
Int soundCheck if +G supply missing - if so check relay contacts
GrundigCUC740
Int dead or int st/byC633 100µ 25v
GrundigCUC740
Int DeadD671 BY299 in 5v supply int o/c
GrundigCUC740
INT CUTOUT , GOING TO SBY OR DEADD671 5v SUPPLY
GrundigCUC740
Excess widthD572 SKE4G2/06
GrundigCUC740
Dead - S1644 1.25A fuse blownT654 BU208A s/c - check for arcing at C634
GrundigCUC740
dead - comes on briefly when tappeddry joints chopper tr and surroundings
GrundigCUC740
Dead - chopper tr blows instantly at sw onR633 27R o/c in base cct - also blew LOPTr
GrundigCUC740
Chopper tr blows instantlyR633 27R o/c in base cct - also blew lop tr
GrundigCUC73xx series ST55-725
Sound faultythe soldered joints on C60029 were very poor
GrundigCUC73xx series ST55-725
Power supply blow upCaused by C60029 470pF 1.6KV which was badly dry jointed. Only seems to affect sets fitted with blue cap - the orange ones are ok.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.