Dicas Reparação




Modelo - Chassis CHASSIS


Pesquisa: CHASSIS Enviar Dica Resolvida
Resultados 452
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
NEIE5 CHASSIS
Squealing noise tho' works ok - T651 hotD653 s/c - BYT52M
NEIE5 CHASSIS
Servicing the NEI E5 CHASSISSee TV mag July 1999
NEIE5 CHASSIS
PSU low O/P - appears to be trippingD652 BA157, C657 47µ R664 10R o/c. T651 BUZ90AF low gain - if volts across C665 is 260-270v replace it
NEIE5 CHASSIS
Pic bowed or lack of widthC753 680nF 400v
NEIE5 CHASSIS
No raster - no/low line driveCheck D701 1N4148 clamp diode, D705 BA157 leaky, line dr trfmr pri winding hi res (should be 4R3) ot IC101 jungle chip
NEIE5 CHASSIS
No raster - volts across T702 400v instead of 1kv C709 's' correction cap o/c, if so C710 2µ 350v, R709 10k fusible may have failed
NEIE5 CHASSIS
LOPTr goes s/c at sw onD705 BA157 s/c or crt internal s/c at final anode, C124 2n2 o/c (pin 39 IC101)
NEIE5 CHASSIS
Line freq incorrectC122 4n7 leaky - pin 40 IC101
NEIE5 CHASSIS
HT low - max of 140vP651 HT preset 2k5 fallen in value
NEIE5 CHASSIS
Dead - no o/p from psuCheck for R654 820k o/c, C665 o/c, IC651 faulty
NEIE5 CHASSIS
Dead - Chopper tr IC651 & control chip IC651 s/cD653 BA159 s/c use BYT52M as replacement & check tracks for damage
NEIE5 CHASSIS
Chirping at low brightness with line jitterR655 330k & 1M across it hi res
MitsubishiCT25MSTX E14 CHASSIS
Dead - st/by led lights briefly at sw ondry joints on IC951. Drys were also found on regulators IC952, IC954 & IC955.
MetzCHASSIS 680G/681G
Starts with black screen, if G2 increased and brightness and contrast are set to max, picture faintly visible.Change TR901 in decoder module. Leak was detected with a VOM.
MetzCHASSIS 680G/681G
Gradual loss of contrast and focus from bottom of screen to top, when increasing brightness or in shiny passages.Change or clean and readjust trimmer pot R857.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads