DIST AUDIO FIRST APPROX 10 SEC AFT CAM ON/RPL C378, PC52 BD Distorted and low audio for first approx 10 seconds afterturning camera on. Has to be off for several hours in order toduplicate.
SonyCCDV5000
NEW MIC JACK PART DIFFERENT INTERNALLY THAN ORIGINAL/JUMPERStandardized Replacement Dual Mic Jack p/n 150779721 has different internal switching from original jack. Because pins 5 and 6 must be cut off to fit board, the Mic audio is lost.
SonyCCDV5000
HORIZONAL BAND LINES IN PLAYBACK/RESLD PIN1, CN605, DI-21 BD Unit had intermittent problems in playback: 1.horizontal bands of incorrect color, 2.colors changing, 3.no video output.
SonyCCDV5000
INTERMITTENT COLOR ON RECORDING/ REPLACE C630Intermittently no color on recordings, E-E and playback are OK. Found defective filter capacitor C630 in chroma processor.
SonyCCDV5000
UNIT SHUTS DOWN WHEN USING BATTERY/REPLACE IC103 Unit ran fine on AC adaptor but would not ooperate withbattery. Tech was not able to perform battery down adjustment, no matterwhere set unit shut down at 6.3 volts. Battery sense line at themicroprocessor was changing when RV001 was adjusted at pin 4
SonyCCDV5000
POOR VIDEO IN FORWARD SEARCH (TEARING): REF 304 LEFT COASTER Unit had excessive hitches in forward play, forward search hadan unusable picture.
SonyCCDV5000
BLOWS FUSES, CAPSTAN FLEX RUBS THROUGH Unit had F603 open. Found that FU70 board was rubbing thecapstan motor flex cable. There was no FU insulating plate.
SonyCCDV5000
UNIT DEAD NO LCD FOUND Q106 OPEN, So even with ever 5V units MICRO (IC101) DIDNOT DETECT BATTERY IN. -HQ COMMENTS: IC103 is the voltage regulator IC. The voltage detectorIC104/IC105 then commands Q106 to switch between Lithium or Batteryvoltage.
SonyCCDV5000
TIPS FOR PIX NOISE I have noticed, on these units, if you see white snownoise in the pix, then usually the head is defective. If, however, you seedark dropouts or streaks in the pix, you can usually expect both the headand RP amp to be defective. In either case, remember
SonyCCDV5000
NO EJECT OR OTHER FUNCTIONS. TAPE JAM/REPOSITION TENSION ARM Reference FPR #L0970. Tension arm jumped track, tape onwrong side, will not unthread. Repositioning tension arm allows unitto work OK. Problem then cannot be duplicated. This has been seen onseveral units. Seems to occur the first time a new tape i
SonyCCDV5000
NO VIDEO No EE or PB video. Using the CCDV5000 troubleshooting guide,we traced the signal up to pin 16 of the HD8 HIC board, but a very weakone coming out of pin 20.
SonyCCDV5000
INTERMITTENT DIGITAL EFFECTS/CHECK CONNECTION CN603 Picture on EE and PB was OK, but digital effects did notwork.
SonyCCDV5000
VERY DISTORTED REC. PICTURE/REPLACE C-451, PC-35 The unit will play pre-recorded tapes with some noise. Ireplaced the video head and playback was fine for pre-records but it wasstill very noisy for self-recordings. I found pin 7/CN-303 at about 0.9vinstead of 4.9v which was caused by a leaky C-451- s
SonyCCDV5000
BAD PB PICTURE- NO LUMINANCE In PB mode, the video out contained no Y signal. I traced itto pin 23 of HD-8 board on VI-66 board and there was a good signal. Then,I checked for output on pin 20 of HD-8 board and found noise. I checkedpin 20 of comb filter IC on HD-8 and found nois
SonyCCDV5000
AUTO FOCUS QUESTION We need to know at what point the auto focus sets the lens ata fixed point when in wide angle zoom. We cannot locate this informationin the service or owners manual. Are we overlooking it or does this modelhave a different mode of operation?? Please l


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.