SintomaCausaSoluçãoPor:
FergusonICC9 D51ND
Audio I/p via scart missingTX03 BC848B sm s/c
FergusonICC9 D51ND
Arcing effect on picCheck EHT lead is firmly secured LOPTx end
FergusonICC9 - DPL
Service mode - enteringSw on ac mains whilst pressing blue txt button then press blue button again. Exit set up by pressing 'st/by'
FergusonICC9 - DPL
Height reduced, menus wrong, no pic, search tuning erratic etcSelect serv mode & set up the 3 menus to factory default then reset menus - see full explanation by Dave Hewitt
FergusonICC9
Vert lines down middle of picCL23 8n2 by loptx o/c
FergusonICC9
when st/by selected will not come back on unless sw off firstDP87 LL4148 & CP87 4n7 both sm near remote sensor
FergusonICC9
Weak lum & flashing linesNot TX16 but TC02, 03 & 04 changed & cured it
FergusonICC9
Wavy' pic & IP03 7809 reg overheatsIP03 = startup/st/by supply TL64 BC848B sm leaky - see TV Oct 00 for more details
FergusonICC9
Video poor & streaky & no TxtTX09 BC858B sm tr leaky
FergusonICC9
Video playback - top pic disturbanceUse Chan 9, 19, 29, 39, 49, AV1 or 2
FergusonICC9
Video fault - contrast variesTH 01 (BC848) first sm transistor after I.F can .
FergusonICC9
Tuning slightly offTrimmer in IF unit may want tweaking or replacement
FergusonICC9
TripsIf removing TP66 gives normal operation replace TP66 BC858B & TP69 BC848 in sec trip cct
FergusonICC9
St/by only at sw on with burning smelldis pin 19 IV02 STV2160. If now works trip cct faulty; check TP66 BC858B & TP67/69 BC848 sm
FergusonICC9
St/by onlyJungle chip IV01 removed, cleaned & replaced


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.