ThomsonICC9 37MG73J
Pic break up with folded horiz lines at bottom halfRF11 safety res 1R5 o/c pt no 15022560
ThomsonICC9 37M973J
service mode enteringSwitch on holding in Blue Txt button then press blue button again
ThomsonICC9 37M973J
E-W bowingIV01 STV2160 replaced & uprate CV46 from 10nF to 22nF sm; RL45 3R3 o/c, LL08 pt no 10092690, CL42 4µ7 160v
ThomsonICC9
Trips on & off aft 1 minOK when you s/c TR96 sm st/by tr - TV92 sm was the cause even tho it check ok out of cct
LoweC9003
Relay on front PCB energized but volts at PSU main Cap <300V (No start up as there is <7v to TDA 4601Relay on Front panel is defective, it make contact only briefly (you cannot turn the set on by s/c relay contacts )
LoweC9000
Field - lack of height27v supply low, C656 2200µ35v & T658 BD139
LoweC9000
Dead fusible link R504 o/c & 315mA fuse in LOP o/c - LOPTx
ITTCVC9
Sound - loss of sound.VDR R409 use a VA8650 from wVe.
GrundigCUC95
No pic, heaters or EHT - no line pulses from TDA1950EHT cap had been arcing and caused demise of TB chip TDA1950 & TDA1770 field chip
GrundigCUC95
Field collapseall 3 field pre-set pots had been twiddled & broken - replacement cure
GrundigCUC95
FIELD COLLAPSER2754 1M PRESET
GrundigCUC95
Dead - BU208 s/c.R646 high.
GoodmansGD2880A ICC9
TV works ok but LED red not GreenTR28 BC858B sm s/c
GoodmansGD2880A ICC9
St/by onlyTP66 BC858B sm
GoodmansGD2880A ICC9
Int deadVolts around TR85 BC848B & TR87 BC858B incorrect - Trs faulty


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.