Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Lowe | MS56 C8001 | Dead - st/by only | Line dr Tr supply res R534 3R3 o/c also check C534 47µ | ||
Lowe | C8001 | E-W faulty | R583 22R & IC1581 TDA4950 | ||
Lowe | C8001 | Dead - LOP stage not working | T534 BD137 s/c b-e; upgraded to a TIP41C as original ran hot | ||
Loewe Opta | PROFI S28 C8001 | NO LINE DRIVE | T534 SC USE TIP41 | ||
Loewe Opta | MS56 C8001 | DEAD STBY LED LIGHT R534 LINE DRIVER FEED OC | REPLACE R534 3R3 T534 C534 | ||
Loewe Opta | MS56 C8001 | Dead. | LOPT SC , R583 OC 22R , IC1581 SC TDA4950 | ||
Loewe Opta | C8001 | PICTURE NAOW + TUBE LOOKS POOR HT LOW NOT 142v B | C652 47uF 250v | ||
Loewe Opta | C8000 | WHISTLES + HIGH HT | C638 | ||
Loewe | MS56 C8001 | Stuck in standby. | R534 ( 3.3R ) o/c , T534 , C534 ( 47uf ) | ||
ITT | CVC800 | Startup - will not start from cold. | R731 ( 820k ) high. | ||
ITT | CVC800 | Startup - will not start from cold. | R744 ( 100k ) . | ||
ITT | CVC800 | Startup - Intermittent start up. | C757 ( 10u F ) | ||
ITT | CVC800 | Snowy pic | 1st RF Amp BF960 in CMR800 faulty | ||
ITT | CVC800 | No field sync | 100µ cap next to SAWF in CMR800 | ||
ITT | CVC800 | Dead. | C757 o/c low 110v rail. |